View larger
1SDA072152R1 ABB E1.2N 1000 Ekip Dip LSI 3p WMP
1SDA072152R1
072152
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for rigorous industrial environments, the Abb 1SDA072152R1 circuit-breaker provides reliable automated interruption of hazardous overcurrents to protect electrical assets. Facilities rely on this hardware inside distribution assemblies to manage heavy electrical loads and prevent system downtime.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 232c58d0-7213-4e58-b1e0-8e1e5372516c Italy
- Simplified SCIP: 7bc1571d-03db-4068-8173-545abda5152b Poland
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1NQEGAB000A000000XX
- EAN: 8015644760021
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 232c58d0-7213-4e58-b1e0-8e1e5372516c Italy |
| Simplified SCIP | 7bc1571d-03db-4068-8173-545abda5152b Poland |
| 8862bed0-f4c7-422e-8fab-a1da6d5cfc72 Sweden | |
| 76b6fcb0-7843-4f1a-bab8-ad0c882457fd France | |
| bbeef049-5b47-44d4-8662-84581775f858 Germany | |
| f4afb81c-d53d-40e3-89d6-f49d3577dbed Germany | |
| 085fe989-4697-4f6f-8b70-caea6e5e5aef Hungary | |
| ddb03b50-bf89-4c48-b578-ed1d7428b690 Czech Republic | |
| c80cd1ee-42a6-4ca6-ab0a-6bc4b8e91d53 Estonia | |
| 2d53e729-01f8-4485-8078-97508d04088d Poland | |
| 0f622baf-c602-4a7c-907e-ce300cc42728 France | |
| cf3a5d23-7e80-4dce-a254-d73234a52212 Greece | |
| 92553eed-fabc-4085-aad2-0573a869cf3a Hungary | |
| e94946ac-7ab3-4e10-a602-988c1cbf8071 Spain | |
| b30e24e0-690c-4611-b4ee-ba19f613ea06 Sweden | |
| 2b574201-eff1-41fc-8b03-ace3e83a6959 Netherlands | |
| c80cd1ee-42a6-4ca6-ab0a-6bc4b8e91d53 Estonia | |
| 77a57845-868d-4935-9e2f-f03633d1740a Portugal | |
| 2d53e729-01f8-4485-8078-97508d04088d Poland | |
| 2b574201-eff1-41fc-8b03-ace3e83a6959 Netherlands | |
| dbb99f3a-b824-46de-afc0-328c1511743b Poland | |
| 999e14b9-b5d4-4e49-b3b4-68a3adc7addf Croatia | |
| c06a836d-098c-4325-8a14-47c74b55abc5 Belgium | |
| 7e78f459-59f7-41a3-8288-2fdaacba1bc4 Finland | |
| 4ddfea05-090c-41ae-8769-9969a6fc728a Germany | |
| 49cc758e-f4cb-4f4d-a2c2-25e96c4256b2 Germany | |
| 49cc758e-f4cb-4f4d-a2c2-25e96c4256b2 Germany | |
| f13c2b98-3a00-4198-a580-a131cd45d919 Germany | |
| 3d1402f1-97ce-4561-9ae2-cec3d68c5bca Denmark | |
| cf3a5d23-7e80-4dce-a254-d73234a52212 Greece | |
| 7bc1571d-03db-4068-8173-545abda5152b Poland | |
| dbb99f3a-b824-46de-afc0-328c1511743b Poland | |
| 4ddfea05-090c-41ae-8769-9969a6fc728a Germany | |
| 44f4e1e5-5822-4f40-8302-17818a734d3a Norway | |
| c06a836d-098c-4325-8a14-47c74b55abc5 Belgium | |
| 822af179-b72e-4350-a226-fb435e249718 Belgium | |
| 857f6ae0-de80-4b06-ac1b-eb986f3b9820 Bulgaria | |
| 3d1402f1-97ce-4561-9ae2-cec3d68c5bca Denmark | |
| b30e24e0-690c-4611-b4ee-ba19f613ea06 Sweden | |
| 7e78f459-59f7-41a3-8288-2fdaacba1bc4 Finland | |
| f13c2b98-3a00-4198-a580-a131cd45d919 Germany | |
| 92553eed-fabc-4085-aad2-0573a869cf3a Hungary | |
| 0f622baf-c602-4a7c-907e-ce300cc42728 France | |
| e94946ac-7ab3-4e10-a602-988c1cbf8071 Spain | |
| 822af179-b72e-4350-a226-fb435e249718 Belgium | |
| 77a57845-868d-4935-9e2f-f03633d1740a Portugal | |
| ddb03b50-bf89-4c48-b578-ed1d7428b690 Czech Republic | |
| 999e14b9-b5d4-4e49-b3b4-68a3adc7addf Croatia | |
| bbeef049-5b47-44d4-8662-84581775f858 Germany | |
| 8862bed0-f4c7-422e-8fab-a1da6d5cfc72 Sweden | |
| 44f4e1e5-5822-4f40-8302-17818a734d3a Norway | |
| 76b6fcb0-7843-4f1a-bab8-ad0c882457fd France | |
| 085fe989-4697-4f6f-8b70-caea6e5e5aef Hungary | |
| f4afb81c-d53d-40e3-89d6-f49d3577dbed Germany | |
| 857f6ae0-de80-4b06-ac1b-eb986f3b9820 Bulgaria | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1NQEGAB000A000000XX |
| EAN | 8015644760021 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644760021 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 156 W |
| Rated Current (In) | 1000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |