View larger
1SDA071386R1 ABB E1.2C 800 Ekip Touch LSIG 4p F F
1SDA071386R1
071386
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB fixed-type air circuit breaker, referenced by the 1SDA071386R1 ABB E1.2C 800 Ekip Touch LSIG 4p F F part title, acts as a primary protective device in electrical power systems. Facilities rely on such components to guard infrastructure against overcurrents and faults, ensuring uninterrupted operational safety across diverse industrial environments.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 7ee22573-48fb-4292-ae47-1f82d17b3b48 China
- Simplified SCIP: c384c73e-acbd-436d-bc96-41a9a3cbe460 France
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZACPEFBF000A000000XX
- EAN: 8015644752361
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 7ee22573-48fb-4292-ae47-1f82d17b3b48 China |
| Simplified SCIP | c384c73e-acbd-436d-bc96-41a9a3cbe460 France |
| 6fc89720-8506-4e3a-99f5-f6db103a9456 Germany | |
| 3a9af22e-bf86-4fa0-8037-041b18e898a0 Poland | |
| b044f01d-496c-4199-a558-bf34b2d75664 Poland | |
| 8e8651b0-03b6-4999-8140-bd30368223a5 Norway | |
| 12c2907e-5cc7-4608-98f4-512eaa122782 Hungary | |
| 323d87b9-a91c-4062-96cf-3e739090c0c3 Estonia | |
| 266e9278-fb3e-46f3-a8ca-0a565737ff89 Sweden | |
| 24d17db1-0d81-4be4-bfc4-8e777cb015a3 Spain | |
| 3601467a-90d5-4610-a22c-25c3c4646921 Belgium | |
| c7875992-760b-4fa1-a100-5eb617f2f5e0 Hungary | |
| 322647ce-6787-4c25-86e0-2fb14a28f45a Croatia | |
| 3cc24875-30ef-4654-9b84-954631d12a55 Greece | |
| a32264e8-9fe4-4973-97e3-8440c3821284 Germany | |
| 91953860-f098-4d8c-ac70-3ecefc8c6f34 Portugal | |
| c6327ccc-662f-4569-ab04-d8887e848683 Bulgaria | |
| 17fee127-cbdd-453d-ae53-a564cdafdee2 Sweden | |
| 44b04276-7afb-4dda-adf2-99123cafc50b Czech Republic | |
| 17e1eb82-a52d-44dc-b775-ca1f94943f3d Germany | |
| 7431da2e-d99c-4665-9ce0-8346c30f8c15 Poland | |
| 17d0bbbd-b6f7-44de-b475-707e28b3ae1a Netherlands | |
| b8c1ed0c-970b-4b6c-a11c-1fdbbe6d739a Denmark | |
| 94aeff5a-2bc6-4a2c-be73-f76d898f759f Finland | |
| 524b8dcd-3090-4ae0-ab42-649640f22bd0 Germany | |
| 3bb0dd01-dfd7-4273-b39f-a6a183a8b78b Germany | |
| 3f6b5c25-34d7-40f6-bbf7-774e0fcd5d12 France | |
| c2d48136-f576-4db8-adbd-8860b5d35c29 Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZACPEFBF000A000000XX |
| EAN | 8015644752361 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644752361 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 50 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |