View larger
1SDA070756R1
070756
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 16afd69f-328d-4432-b352-fe9919109fc5 China |
| Simplified SCIP | e3a9d541-b0ac-459e-806f-15b868ab1987 Belgium |
| 233cf28c-84b6-41cb-a415-59dfa92ffc8d France | |
| ff53dc91-8476-4770-9143-3251e0064984 Germany | |
| 4bea323e-67bd-494d-8b46-9e475f8d78b3 Finland | |
| f3b7de89-4a5e-4ddf-afe3-41c4e0477062 Germany | |
| 4fe0fe8a-f82a-4d3c-a903-a960cd08f541 Germany | |
| 672d9c2c-98e2-45fe-b9e0-d537552f36d4 Denmark | |
| ba647b7e-e3e5-4895-8f08-7dbb9c88d139 Poland | |
| a4016106-ddef-4c24-8a84-2afdac56a2d6 Spain | |
| 0cc20d2d-c642-485d-b5a5-5b08cb6eda44 Hungary | |
| 2fc70c19-ca94-4522-b370-a68b357eff9e Croatia | |
| d78ddc76-74f8-47fa-842f-786c263730f9 Belgium | |
| 89cd00ac-f975-4277-8c92-89a500b3d19d Estonia | |
| 83d08976-94c6-4d5e-a96c-5c2b021d0fd0 Germany | |
| ca181131-1d20-4d57-8884-aa6e8dd5f506 Hungary | |
| 1344884d-43d8-42d6-9078-ab9e94294382 Bulgaria | |
| 4da99c3f-3b24-4fff-ac43-33a6613fca9d Poland | |
| bc71f67f-abcb-48ca-b024-9d92319a4878 Norway | |
| 387edc5b-43dd-4e8a-9b3c-70af9c0b6dcc Sweden | |
| 86b4d933-5020-44ac-97e2-3c3f0c12e625 Portugal | |
| cc40550d-6a87-43a4-94e4-5450a4ef9bd5 Poland | |
| ceb166a3-753d-4b10-9ce0-90c2da399c67 Netherlands | |
| 55d22916-4f00-419f-a730-f2228553c698 Czech Republic | |
| 214e1178-f07b-4b09-8bcf-5db578552c0a Germany | |
| 357f4ab5-8391-446d-a25e-6b78878c1897 Greece | |
| 899529d4-93bc-49cb-92c2-ebcb6e93b044 France | |
| 293fbfea-ff47-4ca9-9b1b-04f7f5f81cc5 Sweden | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1CPEFBF000A000000XX |
| EAN | 8015644746063 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 14 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644746063 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 50 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |