View larger
1SDA072104R1
072104
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2360 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | a7cad8cc-daa1-4ccd-b05c-5ee1a435f4d1 Italy (IT) |
| Simplified SCIP | 6b8bbf0d-b788-4335-b7ec-a81e58a97157 Germany (DE) |
| d60b0457-c200-4301-a42a-b8381217a1d5 Sweden (SE) | |
| fdab8b19-3e39-48ae-9c4d-e733a3816397 Czech Republic (CZ) | |
| 30c5011a-f69f-4849-8fdf-a8ef3b42c60c Poland (PL) | |
| f82e0866-4c3d-4d3a-bd1d-61b297ed7db6 Germany (DE) | |
| 5e5ad845-8802-4257-b4c2-a0f7e32986d4 Germany (DE) | |
| 2c0389d9-26be-4723-b13d-0cbf36f6b219 France (FR) | |
| 7e45f540-b3b0-4774-95f5-cbee0799155e Netherlands (NL) | |
| d45597de-3c4f-4271-b736-9b3a5888a0ef Germany (DE) | |
| a3e348c7-56b7-4b6a-8278-cf39a00b7121 Hungary (HU) | |
| e24f22aa-6a0a-4a72-ba5d-8822f086a494 Estonia (EE) | |
| f02de4bf-61bf-48b9-8ef0-ab7130ce21a6 Greece (GR) | |
| 7863ed85-e7ea-4736-b85d-f3c63a3df794 Portugal (PT) | |
| 5d6de351-a75e-4152-8136-85b0e405592e Bulgaria (BG) | |
| ab6005ad-87d3-4d39-9b5f-54c47f3a4b19 Denmark (DK) | |
| 65f8b40d-52c5-4a43-9e7a-60cb975a37cd Germany (DE) | |
| 7d5f8df1-1467-46e1-a418-f41edc8f7e44 Croatia (HR) | |
| 037c44fc-0db9-40a3-bc8d-60a16781c548 Finland (FI) | |
| 261b1e8d-c83d-47d8-a7f9-abd4fd017fbd France (FR) | |
| 14c26c90-7dd8-4615-85aa-79f2ddd81d2d Norway (NO) | |
| b11a6c45-650e-4661-a2ec-7942a211a880 Poland (PL) | |
| e5efd5a1-2cf8-4d38-b1dc-059b24b508ed Sweden (SE) | |
| 0967063d-6966-41b2-be00-deb839a3cfbd Poland (PL) | |
| e637c487-ecce-42ac-818d-1da758c6b92a Hungary (HU) | |
| ae6218d8-f65d-41fc-aaa6-46fcc194b723 Belgium (BE) | |
| c24a2de9-45e9-4fae-a3ef-fe8f980ab9c2 Spain (ES) | |
| a283ec61-f2c1-48c6-991a-66bfd12164c6 Belgium (BE) | |
| Ordering | |
| Order Code US and Canada | Z1CPEFAD000A000000XX |
| EAN | 8015644759544 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644759544 |
| Additional Information | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3 |
| Power Loss | 100 W |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Current (In) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Release | Ekip Touch LI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |