View larger
1SDA070754R1
070754
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 24907a13-4f80-4010-b37f-c9dcca7337c1 Italy |
| Simplified SCIP | 88a15b2d-d66e-44e4-bc4c-c3316879139d Denmark |
| 0d192a6a-1365-401d-bce3-da74ecc034ff Germany | |
| 5ca8800b-87e9-4c6e-b7d1-4a436ea15477 Germany | |
| 33542eac-a268-4cee-8b69-bdaa971fab59 Croatia | |
| 82942590-a724-4e6f-9b6c-1c9d47a9ce86 Germany | |
| 81dc65f7-a034-457c-ad81-97f31992afce Sweden | |
| 15c3979c-3719-48e9-b86f-85afd95a94b0 Hungary | |
| 139241cb-f9c6-40c8-845a-985ba3143e9b Czech Republic | |
| 4fb9083a-60ae-4583-8743-5a617172a8a8 Finland | |
| 08c3a68f-8ded-4060-b446-cbb1a058b8fa France | |
| f6473496-de11-48ab-abf6-dc520591c802 Norway | |
| d36ffc76-de62-478e-8a4f-5c2028335aee Greece | |
| fe0c5e4c-9e2b-4419-bf0c-3875fd96ddf0 Germany | |
| a4f686c2-7d41-495a-957b-0c582eb68875 Poland | |
| 1c8aff1f-122a-4b47-af70-1ec1ea40c061 Poland | |
| d16c0689-4cf3-4700-bbcd-4e0dc5c62668 Netherlands | |
| c1782dc1-c8bc-4df5-b9f0-f0060b829c6f Hungary | |
| a5c0b7fd-df20-4648-a8c8-dd16b8e9db5a Spain | |
| 5d2fda53-cb3f-444d-be83-c450907b648b France | |
| 43e23447-000c-435e-aba4-4675c041fead Belgium | |
| a7709a69-0221-4afe-91a5-691d44c0937b Portugal | |
| cfd3bdbe-04a3-466b-8bff-b8c9d1f75445 Bulgaria | |
| b0c0722e-f953-4858-98a3-df1d2acc0f3e Estonia | |
| 698e46d6-bed6-4baa-8c6d-f75fe2486f8c Poland | |
| 7154cb51-412b-4ded-8bd2-160164212c47 Sweden | |
| e5f06013-1376-43fb-974d-04b78863c70c Belgium | |
| 28b04bc9-66d4-4b50-95b8-e6a662f4791d Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1CPEFBD000A000000XX |
| EAN | 8015644746049 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 14 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644746049 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 50 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |