View larger
1SDA072101R1 ABB E1.2C 800 Ekip Dip LI 3p WMP
1SDA072101R1
072101
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 1SDA072101R1 E1.2C 800 Ekip Dip LI 3p WMP is an withdrawable air circuit-breaker configured for main distribution switchgear. It provides robust fault interruption and system monitoring capabilities, ensuring maximum uptime and safety across complex electrical infrastructure.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 00481da2-8021-42e3-a155-3564d0c07083 India
- Simplified SCIP: 402b8139-0a06-47c8-ab0a-f92c97e3d89a Hungary
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1CPEFAA000A000000XX
- EAN: 8015644759513
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 00481da2-8021-42e3-a155-3564d0c07083 India |
| Simplified SCIP | 402b8139-0a06-47c8-ab0a-f92c97e3d89a Hungary |
| e0d25b9f-230b-4b11-8843-63c395f49ef0 Hungary | |
| c78dd83b-ba2c-4dda-9f3b-e3e9ea9e1262 Netherlands | |
| 32116ee0-6c69-44ff-b1f0-3e5849d85258 Norway | |
| 0db7ed48-8248-4f79-99e8-35c24f87f8d5 Belgium | |
| 6c66c0b3-01c2-4f6f-8143-0974d49ba7ee Denmark | |
| a47de024-2565-4a5f-a4f8-117d68fbd0f4 Germany | |
| 76e1f4fd-ebe7-4850-a036-85e21ee46959 Poland | |
| 52b52d9e-eee3-431f-97cc-4adc1c907299 Czech Republic | |
| 25ae465b-f371-427e-a9a7-2da1ef9644ac Croatia | |
| 3ae27e78-2504-41fc-9530-11600eac603d Belgium | |
| 9a6d35f4-8784-43cd-948b-5f48d207bd97 Spain | |
| 212974c8-a825-48d8-be67-c10acc1281c5 Estonia | |
| 71b9f2a8-5209-4e73-8455-2fa9792e6082 Portugal | |
| c50d148e-db89-4327-9e37-e3427559fe93 France | |
| 4079f4ba-6b0e-41d5-9ed6-1a0887c6e71a France | |
| d5972a58-71b4-4025-9739-4f9824a7392b Sweden | |
| fe034484-c71a-4558-8856-7f4fe8f6e601 Germany | |
| e8a5570e-5646-4eb2-9010-5f5a5bf9aefd Germany | |
| d12012e5-063f-41c7-bd36-090e0f67e0a8 Bulgaria | |
| 74ec9478-ddb6-4075-9b01-77950e83433c Poland | |
| 2919a714-c145-4ce4-8bf2-6a8eddd776fe Sweden | |
| d9582723-dd16-4c72-9a37-75bdca91302b Greece | |
| 37db113c-daf0-48ca-a990-d076c3d1e9c4 Germany | |
| 9dd32509-25c1-4e76-baee-eebae7ea39a5 Poland | |
| 60ae9838-0a3b-4f0e-a0c6-3ed4d12f9d94 Finland | |
| cd203d8d-1ec2-4af8-8879-f7605bfe59d9 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1CPEFAA000A000000XX |
| EAN | 8015644759513 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644759513 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 100 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |