View larger
1SDA070751R1 ABB E1.2C 800 Ekip Dip LI 3p F F
1SDA070751R1
070751
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb E1.2C 800 Ekip Dip LI 3p F F circuit breaker is an engineered electrical interrupter designed to safeguard three-phase power lines against overcurrent and short-circuit hazards. Industrial facilities integrate these reliable circuit breakers into switchgear assemblies to ensure secure and continuous electrical distribution.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: b315e7a7-7676-4676-a4af-6622c1b3507e Italy
- Simplified SCIP: 191a63c6-de88-4268-b3b6-173c5f0bb6a2 Czech Republic
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1CPEFBA000A000000XX
- EAN: 8015644746018
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | b315e7a7-7676-4676-a4af-6622c1b3507e Italy |
| Simplified SCIP | 191a63c6-de88-4268-b3b6-173c5f0bb6a2 Czech Republic |
| 7f4eb7b7-a61f-467b-9c76-0122e1f40d4b Germany | |
| f123b720-0846-4de3-a43e-93122a890f02 Sweden | |
| 547328fd-e8cc-42af-8545-e98f65456468 Germany | |
| 08d8f836-f199-413f-b130-0dcf7b76e697 Hungary | |
| 6ee0fd72-bc20-4cbd-9386-8f7d9747a7ae Bulgaria | |
| ba8915b2-61b1-494a-8eca-e59773346c2a Germany | |
| 89718cd2-80ce-4bd0-b198-6dcbcbaddfdc Norway | |
| 81aa6ec7-6725-4d78-ad6a-8a9ec243b740 Germany | |
| 632fee04-e082-435d-b506-667fb3ae433b France | |
| 15a75ea6-87db-41c5-8aae-2b11c19cd5ca Finland | |
| 1df436f8-11df-4a6a-867d-11b8003ce188 Croatia | |
| c5a4ab64-cff1-4149-8c6d-797f1e8bcfee Poland | |
| e9d4d5dd-5a78-4923-a415-8e445a0f420d Netherlands | |
| 3246ead9-5cb6-4aeb-9409-84753b888647 Poland | |
| 25962849-0630-4d20-9a18-cdd2e34c4c80 Belgium | |
| 041943a3-8e8d-4d76-9b3c-4705bd73d831 Belgium | |
| 6c6fe3ab-3540-47b4-9e7f-34f5dc783303 Hungary | |
| a5082cfe-38d5-48a3-8d66-6d5bf40f8ce8 Spain | |
| f3c5dd24-e566-413a-8c80-f2428547c275 Portugal | |
| ef6e1088-e7aa-4e81-842c-840a2e36cd13 Sweden | |
| bde72632-1ea4-4c67-a444-b3092536066d Poland | |
| 32120508-5ac9-4dcb-a885-1f1956ba849c France | |
| 644a18c1-9a1d-4046-b4e4-31b0dd0660a4 Greece | |
| ec9fc84a-49cd-450d-8d9b-7f0c6e8a8051 Estonia | |
| 801aa307-a290-43bf-8337-b14f9be3f8dc Denmark | |
| 8802d1c8-1ec5-4da1-92fc-3f0c4d365106 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1CPEFBA000A000000XX |
| EAN | 8015644746018 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 14 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644746018 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 50 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |