View larger
Images are for illustrative purposes only. Please refer to data sheet for details
1SDA072063R1 ABB E1.2C 630 Ekip Dip LSIG 3p WMP
1SDA072063R1
072063
ABB
1 Pcs.
E1.2C 630 Ekip Dip LSIG 3p WMP
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The 1SDA072063R1 ABB E1.2C 630 Ekip Dip LSIG 3p WMP is a withdrawable air circuit breaker utilized for power management and electrical safety. Systems rely on these breakers to isolate distribution branches and interrupt high fault currents.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: b0467276-9f40-4a68-a13d-6b166957706d India
- Simplified SCIP: 1203ee2b-8610-4d1e-a511-9a33b7e036fd Denmark
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1CNEEAC000A000000XX
- EAN: 8015644759131
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | b0467276-9f40-4a68-a13d-6b166957706d India |
| Simplified SCIP | 1203ee2b-8610-4d1e-a511-9a33b7e036fd Denmark |
| 889a0793-12bc-4a00-86e3-5d292303267b Croatia | |
| 9a75f57d-4384-416d-a594-0658a8451708 Czech Republic | |
| 9024ff27-5ff1-45d5-a04c-dadf4c1c45e6 France | |
| aba35870-9e99-4cd9-a311-2ae7e0720a29 Germany | |
| 4ea684b1-3059-4a76-9fb5-2c45f99aac30 Germany | |
| 97179440-4030-44a5-aaf9-cf312a8f45fb Portugal | |
| c0dc9400-bf3f-4d91-9df9-a748ccf8dfee Greece | |
| 224f2a3b-6d96-4e5e-840e-cca54f67f6f6 Estonia | |
| 3315d91a-2d1b-40e1-8b71-28ed72829d9e Sweden | |
| 9c411f78-b74e-496f-9f81-10204073d28f France | |
| 2236f681-3e12-4092-9c7c-de9a906483bb Poland | |
| a7bc02b1-1efc-4431-8e98-d62b9dacda95 Sweden | |
| 42817471-1838-4d0c-b0be-30aa98a2d4ea Bulgaria | |
| ff00c2cb-26d8-40c6-98f7-5c2110fcf1b7 Netherlands | |
| 62f0b5e0-ed3c-4503-a388-f4edfe56b398 Poland | |
| d0f51711-dcbd-443a-a23d-89046e1cda29 Hungary | |
| 6e6c988b-ae6e-4855-8401-f49f48644376 Hungary | |
| 053459ee-019c-4a32-be62-f2bf9665627a Belgium | |
| bead8ecc-7e43-4f7f-b517-71c9bcb0990a Spain | |
| 8d99aa91-c9bf-4a3f-b621-74a10cb0e828 Poland | |
| 3c67eb11-4e7a-4d28-94ec-c211bdefd3d9 Germany | |
| ecbdc5dc-2c21-4b8f-b7ff-ae8c749d67d9 Germany | |
| a8fb77b3-2301-49fe-9e43-8cdfe61d03f2 Norway | |
| 1a2d47ea-ae9e-40e1-8735-01cba9419533 Belgium | |
| ac5df263-9151-494d-9c86-2d4bc094639c Finland | |
| 23e1fcce-ebf7-4024-914e-5513b1c9d891 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1CNEEAC000A000000XX |
| EAN | 8015644759131 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644759131 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 400 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 62 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |