View larger
1SDA072061R1 ABB E1.2C 630 Ekip Dip LI 3p WMP
1SDA072061R1
072061
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A withdrawable air circuit breaker like the ABB E1.2C 630 Ekip Dip LI 3p WMP provides reliable main circuit protection, isolating electrical feeds during faults or scheduled maintenance in industrial switchgear. This component ensures system continuity and guards against severe overloads.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 6d0618cd-f996-4662-adae-243f2e4b7d2d Italy
- Simplified SCIP: df51b149-6e71-4f73-9940-427c16634f3b Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1CNEEAA000A000000XX
- EAN: 8015644759117
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 6d0618cd-f996-4662-adae-243f2e4b7d2d Italy |
| Simplified SCIP | df51b149-6e71-4f73-9940-427c16634f3b Germany |
| 3e4c32f2-0152-4b79-956c-78fac43e4f1d Portugal | |
| d24a5f5d-b996-4aec-87f5-401f22fb07f4 Czech Republic | |
| 2e824420-42b6-4c26-89b7-55f28841713a Hungary | |
| 7356938d-a8f9-4a9a-a09c-cc77e6c38b5a Belgium | |
| 07aac190-8338-445a-bebd-d83961e3b4c9 Spain | |
| b4802db9-d00f-4106-9cdc-ae9f7b6a3065 Poland | |
| 10344ac5-e15b-4fff-8c12-45e768934b85 Norway | |
| c22ef2e6-876f-45aa-9cdd-cd5f2831e80e Hungary | |
| a2d05866-8d14-43c1-92ec-c8c25e38fcf3 Germany | |
| ecf34d83-7755-403f-ac89-dec110fea1b3 Germany | |
| 713a103d-c92e-4590-ace9-e5a2941045b8 Denmark | |
| 39e876f3-76fc-4063-b826-6e54161ced30 Belgium | |
| 58af985b-d93c-4047-b817-c4dfec054832 France | |
| 7980b906-4af8-4a4e-8ba1-7d450a73a248 Greece | |
| a5d2cc05-777f-4c5c-99c0-f78341191a6c Finland | |
| 5be4b23e-1579-4292-ba45-c9b0f89a7468 Netherlands | |
| ee6468e7-bf66-45fb-b7d1-e05d05f926b1 Estonia | |
| 78e3eb1f-8292-4ad4-9411-2cca971ad535 Sweden | |
| 076fbb0c-6d30-4190-89a7-2ff0bd71375f France | |
| 6b53f1cf-450b-4cfe-9dca-11f7fa9225dc Croatia | |
| 496a7ec8-8654-47ad-80f9-0d9369270a3a Germany | |
| 4f079a12-afb9-4dc8-bda0-74fa89c2b830 Germany | |
| 7286fdb5-2792-44c0-b18f-17b13185ff34 Poland | |
| 235ab62a-4002-4e8c-b76e-4437dc0737bd Poland | |
| c9e3937e-08ae-4935-afac-22b20205b604 Sweden | |
| 4aaf67ee-49d6-415e-839f-cd03747b6ba9 Bulgaria | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1CNEEAA000A000000XX |
| EAN | 8015644759117 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644759117 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 400 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 62 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |