View larger
1SDA071504R1
071504
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 32b6067f-7b9b-4359-a240-6b11b41cf3ba China |
| Simplified SCIP | 4cda4305-734e-454a-89b3-f49b014da7b4 Germany |
| 8d8a59a7-060d-4b60-9494-d989141691df France | |
| 10285412-497e-44ab-9f86-6706a0111eb5 Germany | |
| 6abd9a95-9821-40a5-8b2a-823aea108623 Finland | |
| 127cb30a-ed2b-4684-a98c-fbd97aea28d7 Belgium | |
| 0e82106a-1c96-43c6-87a8-0756a5ec0c38 Germany | |
| 784d698b-ea0c-41a0-9b7b-4666b0136bad Spain | |
| 45ad19fb-b496-4c39-97b5-08d816a7d5a3 Belgium | |
| 4cba4182-1298-418a-a1b7-3776d59fbb26 Norway | |
| b9f0604d-973d-42fe-9109-8a04817384b8 Greece | |
| 0fc1bcb1-9d2d-4da2-b800-babde8c8720f Croatia | |
| cddacf9c-ecf4-4bd5-854d-da4d655c0fcd Germany | |
| 9b1fb6dd-221b-4c13-ba00-e08914ce4e55 Denmark | |
| f711a1f8-fb12-4b5b-a896-fd5635b73f8f Hungary | |
| 24717496-30ca-4a6d-ac54-9bef4514b569 Hungary | |
| 2858086a-f8a4-4369-a8cc-1a1723af83a2 Poland | |
| eaafe8f1-9a42-495d-9242-66d2a16b714d Estonia | |
| f733fd4d-5b47-4d3f-a468-fc6c81fa4541 Germany | |
| ab72e9c1-1ddb-4414-8ccd-2c590d0e487e Bulgaria | |
| f61a33d1-5c20-440e-b74e-ae0e69ddff11 Portugal | |
| 9ee9d874-a41d-409a-a8e1-b1a2c49b79ad Sweden | |
| c8155b48-dbc7-415c-899a-d0abad395c7e Czech Republic | |
| 67c4283a-bb33-4721-b523-dd71ba754fe9 Netherlands | |
| 29d35827-df52-49a9-9633-866c8fc55e83 Poland | |
| 9337b860-079c-4d9e-b0e0-ccb75128ab75 France | |
| 45922073-f29a-45f2-8b7f-c90ba311f499 Sweden | |
| cd3526ca-a5e4-42b4-9960-35e6cb185a0e Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZACSEJBD000A000000XX |
| EAN | 8015644753542 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644753542 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 1200 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 3000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 201 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |