View larger
1SDA070873R1 ABB E1.2C 1600 Ekip Dip LSIG 3p F F
1SDA070873R1
070873
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A 1SDA070873R1 ABB E1.2C 1600 Ekip Dip LSIG 3p F F air circuit breaker is deployed in heavy-duty power distribution systems to provide precise overcurrent protection and reliable electrical isolation. It safeguards critical installations against major faults. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 659a8314-77ec-4149-8c8a-2a0a4a36467b India
- Simplified SCIP: f08ce541-352c-49db-afa7-03e4f46934ef Poland
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1CSEJBC000A000000XX
- EAN: 8015644747237
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 659a8314-77ec-4149-8c8a-2a0a4a36467b India |
| Simplified SCIP | f08ce541-352c-49db-afa7-03e4f46934ef Poland |
| 12c823b7-a67c-45e1-b798-784a7ace538a Croatia | |
| 1d9cee56-cc74-4a6f-b4d5-8c09c770921a Czech Republic | |
| 7187ec5f-e775-441b-990f-00973d64826a Hungary | |
| ce8452eb-e8d0-4068-b281-73f348042266 Netherlands | |
| 01fd1f1c-5287-429e-84fa-3f83347da17f Hungary | |
| dcb5ea15-f9d2-4c86-ac45-9fc87ac84ae2 Spain | |
| 18478cd8-43de-4935-8bc4-c2d818fac640 Belgium | |
| 34c336b0-3c45-48de-9c1e-a39c8a3f3eed Greece | |
| d64597b7-0e68-4bb7-83b7-a265a7a36952 Poland | |
| 2ebc76d4-b894-4adc-aac4-17c866e71c46 Sweden | |
| 038870fe-5b85-43b1-b01b-3b465309b0a3 Estonia | |
| e555fea2-1a73-473b-9e34-bf362dafdbfd France | |
| edead63a-bc1a-42e9-b963-98fac1237346 Portugal | |
| 93b23526-8d2b-45d3-aa54-be315207c00c Germany | |
| 82eb6223-1f9f-4927-a34a-3a2ae8b5c1e0 Sweden | |
| 8c0df97b-8ca2-4b9a-ade3-a55a53ca406f Bulgaria | |
| 57ded92a-9e91-4453-ae9f-436478959ea4 France | |
| 8ffcea2e-0090-40f0-803b-41a134864948 Germany | |
| d4385923-6aeb-4b2e-9bd9-1485c77719f9 Germany | |
| 3af81882-eee4-440e-935a-e9412e840468 Denmark | |
| 9bf51f40-9a10-44b1-ad6e-5ec435b9176d Finland | |
| 91aafe1d-8c02-4ea7-9814-4911c91e6098 Norway | |
| 528ecbd9-0c6b-42b3-8c66-b873ce5e1b46 Belgium | |
| 329b113f-7f5f-42cd-9575-08d12104f014 Germany | |
| 320fe33f-8c35-46b0-b4bf-3254362e1d5f Poland | |
| 256f3703-9288-4363-859c-2e5ba3b552c4 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1CSEJBC000A000000XX |
| EAN | 8015644747237 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 14 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644747237 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Connecting Capacity | 1200 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 3000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 201 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |