View larger
1SDA071465R1 ABB E1.2C 1250 Ekip Touch LSI 4p F F
1SDA071465R1
071465
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A fixed-mounted air circuit breaker, such as the Abb 1SDA071465R1, provides dependable fault interruption and power distribution control in industrial facilities. It protects electrical networks against dangerous overloads and short-circuit events.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: b66fa109-1bc7-4410-b45f-46cf2b17fa0f Italy
- Simplified SCIP: 49a4d8bb-abec-4a9b-9168-8d82d863d2f2 Sweden
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZACREHBE000A000000XX
- EAN: 8015644753153
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | b66fa109-1bc7-4410-b45f-46cf2b17fa0f Italy |
| Simplified SCIP | 49a4d8bb-abec-4a9b-9168-8d82d863d2f2 Sweden |
| 2cdad6b8-9111-49a4-916e-d422daf8f3ba Sweden | |
| 9f3ac5bd-05c2-4bfd-b026-5bb10572d051 Hungary | |
| 5010d247-fe4e-4acd-87b3-9636287b3ff3 Spain | |
| e2f06332-1b5a-459e-a74b-e1ee3341f183 France | |
| 6ebb726f-e72e-4824-a2fa-e60ebe3356d2 Germany | |
| 6df05ba3-c6f5-4b45-84c4-0113ca546764 France | |
| 04065a7e-3248-496f-bde0-dca04c1ebcf8 Germany | |
| 7dd68338-b10f-4b2f-a5da-b329ae8d677c Belgium | |
| 9adb04ad-15e3-42c1-b0bd-ed683b99258a Finland | |
| 994c9c3c-6f85-45cb-bdba-04b3fdb40471 Norway | |
| 740ca01c-94fe-4118-b0e6-7b05b6305e67 Germany | |
| 945dec05-ba5e-4707-bc35-6b829a978d85 Belgium | |
| 4bb9ce96-695e-42db-aab9-cf1664436e8e Germany | |
| 4dfa03a0-f005-4362-b295-99d623259e35 Poland | |
| a1b8cdc3-ec7a-4dcb-af6b-b4d4ec2641d8 Denmark | |
| abce462c-f90d-430d-b7e0-924a3fd3849c Croatia | |
| 3a1ef940-3434-4e25-9a3b-dffdf8b773cb Germany | |
| 63785219-13ac-4084-b5ea-d1fa461f862c Czech Republic | |
| 2da12ea1-58a5-401e-bcd1-117b920d0a66 Poland | |
| ac94ef04-57d9-49d0-bddd-b5b753588cc1 Hungary | |
| bd3ce815-5658-490a-8bc0-bd9811633061 Netherlands | |
| 49383bc4-2899-4997-a3ea-3d26e12067ce Estonia | |
| 16abd3b7-743a-4539-b205-0ebc87d29e34 Portugal | |
| c6d50008-2bd2-4f13-b9d7-7b2d4e2eb0e4 Greece | |
| 26c2b4fb-358c-42db-bd66-f8c1f4f6bfd1 Poland | |
| c20b6301-1b40-4670-9463-41726917f121 Bulgaria | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZACREHBE000A000000XX |
| EAN | 8015644753153 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644753153 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 122 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |