View larger
1SDA070835R1 ABB E1.2C 1250 Ekip Touch LSI 3p F F
1SDA070835R1
070835
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB E1.2C 1250 Ekip Touch LSI 3p F F air circuit breaker acts as a primary protective device designed to safely interrupt high fault currents in commercial and industrial electrical distribution grids. Switchgear engineers implement these advanced breakers to ensure selective coordination and reliable system uptime.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 674f6c80-2066-45af-aed8-15195ccc1070 Italy
- Simplified SCIP: 800a513e-8a52-44f5-b00e-10a62791d032 Denmark
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1CREHBE000A000000XX
- EAN: 8015644746858
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 674f6c80-2066-45af-aed8-15195ccc1070 Italy |
| Simplified SCIP | 800a513e-8a52-44f5-b00e-10a62791d032 Denmark |
| 7302b58c-5380-4a2e-9cb8-e25f0389d6ab Germany | |
| 7e4c06ca-fb02-4375-b239-06de98ae2cd5 Sweden | |
| 55afb1b4-253b-4044-8406-7ffdae5cefb6 Czech Republic | |
| 3e877b1b-c65a-4236-829d-8eed5065d751 Germany | |
| b2cb3bb6-68bb-4a28-910b-ace194e9eece Hungary | |
| 11c19f69-1ded-40a5-940c-a1d3b888f862 Sweden | |
| a7e40697-38ae-4d6d-9118-668e8ea0f910 Germany | |
| eb4e6d41-2638-4976-b405-738a97d0d787 Bulgaria | |
| 58fdee3f-f181-4020-8853-bfd28446ed6c France | |
| b61f0f06-b9ec-401d-a11a-aff9ca6d7d9b Spain | |
| 7302b58c-5380-4a2e-9cb8-e25f0389d6ab Germany | |
| 9d2d711a-e6a2-42a6-a930-dd9de015fd12 Norway | |
| 3c0e6f51-567a-443d-9319-fe2adf706386 Germany | |
| 55afb1b4-253b-4044-8406-7ffdae5cefb6 Czech Republic | |
| eb11462d-ca48-4839-ab1e-9d687a403e49 Finland | |
| 410b1f22-708a-465d-b765-e2101e927ae5 Portugal | |
| 20b356fa-fced-450d-a1e2-1598c8fc7fc4 Croatia | |
| b2cb3bb6-68bb-4a28-910b-ace194e9eece Hungary | |
| 0fdd8c89-cc1c-44ee-b11f-2569f5867920 Netherlands | |
| d5115c0e-f55e-4067-92ce-47ca75cf8416 Poland | |
| aa9f4d21-4ae5-43de-bf1e-36f86e5ac987 Poland | |
| e38f5943-6505-4bc4-9031-e9779101d045 Belgium | |
| a93baf78-2d3b-40b2-8ec6-8e10cbb129a7 Belgium | |
| 2f58ccbe-6a6b-4b17-9a0d-719f2c7b67d1 Hungary | |
| e38f5943-6505-4bc4-9031-e9779101d045 Belgium | |
| b61f0f06-b9ec-401d-a11a-aff9ca6d7d9b Spain | |
| 410b1f22-708a-465d-b765-e2101e927ae5 Portugal | |
| 3f61df14-9111-4130-a024-10b392e889a5 Estonia | |
| d5115c0e-f55e-4067-92ce-47ca75cf8416 Poland | |
| 5a0132ae-e92a-4def-bc1d-d04f00f87041 Greece | |
| 3f61df14-9111-4130-a024-10b392e889a5 Estonia | |
| 0fdd8c89-cc1c-44ee-b11f-2569f5867920 Netherlands | |
| 2f58ccbe-6a6b-4b17-9a0d-719f2c7b67d1 Hungary | |
| a51add93-01c2-4c5b-8135-eeecbf1810fc France | |
| a7e40697-38ae-4d6d-9118-668e8ea0f910 Germany | |
| 3e877b1b-c65a-4236-829d-8eed5065d751 Germany | |
| 11c19f69-1ded-40a5-940c-a1d3b888f862 Sweden | |
| b10ed0ec-3557-4a29-8433-81f2b9e69c83 Poland | |
| 7e4c06ca-fb02-4375-b239-06de98ae2cd5 Sweden | |
| 58fdee3f-f181-4020-8853-bfd28446ed6c France | |
| b4724329-c9fb-4970-8e9f-356388db16b8 Germany | |
| a93baf78-2d3b-40b2-8ec6-8e10cbb129a7 Belgium | |
| 20b356fa-fced-450d-a1e2-1598c8fc7fc4 Croatia | |
| 5a0132ae-e92a-4def-bc1d-d04f00f87041 Greece | |
| 800a513e-8a52-44f5-b00e-10a62791d032 Denmark | |
| 3c0e6f51-567a-443d-9319-fe2adf706386 Germany | |
| aa9f4d21-4ae5-43de-bf1e-36f86e5ac987 Poland | |
| b10ed0ec-3557-4a29-8433-81f2b9e69c83 Poland | |
| a51add93-01c2-4c5b-8135-eeecbf1810fc France | |
| 9d2d711a-e6a2-42a6-a930-dd9de015fd12 Norway | |
| b4724329-c9fb-4970-8e9f-356388db16b8 Germany | |
| eb11462d-ca48-4839-ab1e-9d687a403e49 Finland | |
| eb4e6d41-2638-4976-b405-738a97d0d787 Bulgaria | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1CREHBE000A000000XX |
| EAN | 8015644746858 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 14 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644746858 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 122 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M10 |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |