View larger
1SDA072813R1 ABB E1.2C 1250 Ekip Dip LSIG 4p WMP
1SDA072813R1
072813
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb air circuit breaker (1SDA072813R1 E1.2C 1250 Ekip Dip LSIG) safeguards electrical circuits by automatically detecting and interrupting overloads and short circuits in commercial power systems. It is an essential component for panel builders and facility managers.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: c46c502c-912c-45fe-9b1b-cf072971714e India
- Simplified SCIP: 232b843e-7846-4209-8d3d-6f8f2c41cdfd Netherlands
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZACREHAC000A000000XX
- EAN: 8015644766634
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | c46c502c-912c-45fe-9b1b-cf072971714e India |
| Simplified SCIP | 232b843e-7846-4209-8d3d-6f8f2c41cdfd Netherlands |
| 5e5f2018-9c84-44e7-8b72-7d840d735a04 Czech Republic | |
| bf5c9227-7ed8-49e9-86c7-384b00268cab Croatia | |
| f0fa6529-336d-41da-865a-7096de64ac64 Hungary | |
| ef5aa339-91d1-45b7-8cf6-b640be55b5ef Hungary | |
| f624e39e-6f4e-4eaa-9828-16c1ed179d74 Estonia | |
| 772edce1-e824-4de5-9145-065948b9ab09 Spain | |
| 40e2d490-0ec7-46b5-b3d1-99ae0ab79bb4 Belgium | |
| 8efcd8aa-9796-4a13-8808-bfa5c8a66926 France | |
| d1dd0c71-b4b7-4375-bb55-3a2698ba9439 Germany | |
| e597a51e-56b3-452a-81f2-799422281e21 Germany | |
| 93da6d97-1efb-40b3-a9a4-6036508552cb Sweden | |
| 614a4791-40b6-4719-93f9-05459fb0edce Portugal | |
| b5b19aaf-b7a3-4bf2-af50-0400bfab8f07 Greece | |
| 60f04e31-def8-4b8f-bdaa-d53f8b2aae21 Poland | |
| 40c9ac44-566b-41d5-b74a-7b49c103fb49 Sweden | |
| 74c25bc8-1bea-4734-87a4-f36ebca34329 France | |
| b53893b3-89f4-470a-90ca-b40cf12cc9f3 Bulgaria | |
| 76d47837-1525-4475-9422-12917a79c29e Germany | |
| ca46cdf9-3eea-4d60-b50e-fd69d30d5df9 Poland | |
| a42575c8-84c6-4630-a390-67d34769b3bb Poland | |
| 52b4c39d-1191-4f9b-b89b-a4b444317d6c Germany | |
| 3f023f4c-c114-45d7-8c0d-8e332e807bc8 Finland | |
| 89a53612-4c81-439a-9bbc-6c040599d797 Belgium | |
| 59081551-f755-4bde-80df-bfdd830f7208 Norway | |
| f5f3c5a4-502a-44fc-aaf4-d9c30a6d078b Germany | |
| 151c08c8-e611-4015-b59a-38e8f8e6c300 Denmark | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZACREHAC000A000000XX |
| EAN | 8015644766634 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644766634 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0065 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 244 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |