View larger
1SDA072183R1
072183
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 6b5e68e7-5706-4176-bc1a-65902cdb130b India |
| Simplified SCIP | ab35796a-0491-4587-ba68-955d7f589788 Portugal |
| 8aea8983-193a-476c-b6af-23d812b21fad France | |
| 94bd2b13-8f29-4d6e-8234-da1c99ba8470 Germany | |
| 04a0f6a0-9f79-407c-a285-55499d13a855 Germany | |
| c9d204c0-4d3a-425b-a862-b66fb0112b39 Bulgaria | |
| 1ca9b9a2-3b58-44d6-91a1-e7ba6c89054e Sweden | |
| d0eedf4f-c869-4bf8-af3d-d6fcc024f7aa Poland | |
| 1eeba0f7-bb47-4586-8b4f-9812a407d3fe Sweden | |
| 69c03c26-1cb9-47c5-ac1e-e1cc22b61e59 France | |
| 3d159ddd-3f9d-4732-a21e-1397ddae5f94 Greece | |
| fc4746fa-6ba3-4bae-bb3b-55206120445c Estonia | |
| 6435da9e-57e4-4d44-af26-b16e1261140b Belgium | |
| de94dd57-aaee-4908-8ede-f792422ac9ab Poland | |
| 7e270720-39f1-4249-86da-072d78e72cc6 Germany | |
| de711ee2-15de-4710-8a43-abbc38e40a2a Poland | |
| 3720ad30-71a5-4388-b0f9-61fb717dd305 Norway | |
| 422ce034-b08d-49d9-a46b-9daa57979f07 Denmark | |
| f1acb21d-5643-40d3-8610-6c1174a3f982 Germany | |
| 1dc54746-68d9-485e-a2c1-fabd17c00c26 Czech Republic | |
| b539c246-c418-4321-bf94-c93fbf1e52a6 Spain | |
| 68cc1ff9-7ff8-4a57-ba75-9b3ed65f52ae Hungary | |
| 70adf6b5-99db-4535-8966-f972d186189b Netherlands | |
| 606b38b4-fd18-4e87-aa46-c73c6111f925 Hungary | |
| 70668603-386e-412e-9673-03169c1cbf2e Belgium | |
| 4a8ef36a-48cc-4440-9f64-88f407c546e2 Germany | |
| 0a6f075d-e29b-4e7c-b467-36303338443c Croatia | |
| c43b6d96-91d8-48b0-afeb-b4d61dd59bbb Finland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1CREHAC000A000000XX |
| EAN | 8015644760335 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644760335 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 244 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |