View larger
1SDA072812R1 ABB E1.2C 1250 Ekip Dip LSI 4p WMP
1SDA072812R1
072812
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing advanced electrical safety, this ABB E1.2C 1250 Ekip Dip LSI 4p WMP air circuit breaker isolates and protects complex power distribution setups against overcurrent conditions. These withdrawable components are standard in industrial switchboards where reliable circuit protection and easy rack-out maintenance are required.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 3a481843-82ca-4afa-8af9-d5ecf3c8ba09 Italy
- Simplified SCIP: 079d69bc-992b-49af-b73e-fa4c65190f39 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZACREHAB000A000000XX
- EAN: 8015644766627
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 3a481843-82ca-4afa-8af9-d5ecf3c8ba09 Italy |
| Simplified SCIP | 079d69bc-992b-49af-b73e-fa4c65190f39 Germany |
| 174b81af-a589-4ee2-98f5-535c423d9eda Bulgaria | |
| 4e4708da-6721-4df1-87b3-60dde59a90b6 Czech Republic | |
| 0843c54d-1bbc-49e4-898e-4d988b336e28 Sweden | |
| aa11d1de-635c-416d-91b3-4d8896b44254 Croatia | |
| 7b04ef91-a734-476b-884c-46703e34b990 Germany | |
| a993bad3-0c84-461a-9eaa-a7e72c25caed Hungary | |
| c6d274be-128a-4d4e-8b39-d78ab8ecab57 Finland | |
| bb6ffec0-32e7-48ef-9471-9f9d4184a347 Portugal | |
| 4e4708da-6721-4df1-87b3-60dde59a90b6 Czech Republic | |
| 5a445120-258a-44b7-b5fd-306e5c68dd30 France | |
| 64a6c32a-ee7a-4ad1-bd58-0f750703b791 Spain | |
| 239a1e62-2c8f-4646-bf38-0d9c59ea587a Germany | |
| ea2974eb-0870-4931-9870-60c37961e5b1 Germany | |
| 592573d9-1a78-4b22-87c1-1ddfc7051113 Norway | |
| a993bad3-0c84-461a-9eaa-a7e72c25caed Hungary | |
| 57e578c5-6048-4805-b563-25b8ceab0809 Poland | |
| df578411-19de-4f82-a851-54ded5291b44 Netherlands | |
| f1381d5e-c813-4e28-aced-0ef68b6604d6 Poland | |
| 5dd828d3-9599-444d-bc56-dd32595cc0da Belgium | |
| 90a80982-c170-4d33-87ac-967cd5ed0cb0 France | |
| 64a6c32a-ee7a-4ad1-bd58-0f750703b791 Spain | |
| b733a77b-e789-41e1-b49a-067e0c46dd0d Hungary | |
| bb6ffec0-32e7-48ef-9471-9f9d4184a347 Portugal | |
| 9b87a37c-3c5f-4c92-a51c-c5db32d1ecfb Poland | |
| 57eef0cf-2b0b-465c-a4d8-a1f88973fa75 Sweden | |
| df578411-19de-4f82-a851-54ded5291b44 Netherlands | |
| 74e08c10-09ae-49fe-aad6-457ff542eb43 Estonia | |
| 079d69bc-992b-49af-b73e-fa4c65190f39 Germany | |
| 7b04ef91-a734-476b-884c-46703e34b990 Germany | |
| 0843c54d-1bbc-49e4-898e-4d988b336e28 Sweden | |
| 5a445120-258a-44b7-b5fd-306e5c68dd30 France | |
| 57e578c5-6048-4805-b563-25b8ceab0809 Poland | |
| 74e08c10-09ae-49fe-aad6-457ff542eb43 Estonia | |
| 04e75180-08e7-4e50-9203-5f6211704e2f Greece | |
| b733a77b-e789-41e1-b49a-067e0c46dd0d Hungary | |
| 239a1e62-2c8f-4646-bf38-0d9c59ea587a Germany | |
| 90a80982-c170-4d33-87ac-967cd5ed0cb0 France | |
| 9b87a37c-3c5f-4c92-a51c-c5db32d1ecfb Poland | |
| f1381d5e-c813-4e28-aced-0ef68b6604d6 Poland | |
| 6bd234c7-21f4-4d8a-9860-e00022e39b19 Denmark | |
| 04e75180-08e7-4e50-9203-5f6211704e2f Greece | |
| 7fd52093-28d9-49fa-b610-acf3b7eb0e84 Germany | |
| aa11d1de-635c-416d-91b3-4d8896b44254 Croatia | |
| cec297ce-352b-4d84-aaa1-dc8f68ce7435 Belgium | |
| c6d274be-128a-4d4e-8b39-d78ab8ecab57 Finland | |
| ea2974eb-0870-4931-9870-60c37961e5b1 Germany | |
| 57eef0cf-2b0b-465c-a4d8-a1f88973fa75 Sweden | |
| 6bd234c7-21f4-4d8a-9860-e00022e39b19 Denmark | |
| 174b81af-a589-4ee2-98f5-535c423d9eda Bulgaria | |
| 7fd52093-28d9-49fa-b610-acf3b7eb0e84 Germany | |
| cec297ce-352b-4d84-aaa1-dc8f68ce7435 Belgium | |
| 592573d9-1a78-4b22-87c1-1ddfc7051113 Norway | |
| 5dd828d3-9599-444d-bc56-dd32595cc0da Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZACREHAB000A000000XX |
| EAN | 8015644766627 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644766627 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0065 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 244 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |