View larger
1SDA072811R1 ABB E1.2C 1250 Ekip Dip LI 4p WMP
1SDA072811R1
072811
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A withdrawable air circuit breaker, represented by the Abb 1SDA072811R1 ABB E1.2C 1250 Ekip Dip LI 4p WMP model, is implemented in industrial switchboards for reliable main circuit protection. The withdrawable design allows safe disconnection from live busbars during routine servicing and maintenance checks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 1541e4d8-42d4-4a62-88c5-8c60fc5b4f0f China
- Simplified SCIP: c9fab6a2-bd18-4e6b-a34a-218f859ea40e Sweden
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZACREHAA000A000000XX
- EAN: 8015644766610
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 1541e4d8-42d4-4a62-88c5-8c60fc5b4f0f China |
| Simplified SCIP | c9fab6a2-bd18-4e6b-a34a-218f859ea40e Sweden |
| c7d70b89-4fb8-44ad-8259-2423485cc510 Belgium | |
| 2e46ab1e-4eac-4289-ae6b-fca57f133774 Hungary | |
| f6ecb717-09f4-46ce-ab78-b2c9cb630a05 Poland | |
| 8762e8a5-8a35-4f74-8299-8fac59c12762 Spain | |
| b36df289-c90d-49d7-bcd4-bb1f97b125b8 Germany | |
| 4aaeecb2-aae4-4393-a81a-197d722e7081 Croatia | |
| 6f43afc2-151b-4fe6-87ad-e66e3efbf229 Norway | |
| ba5b7082-9676-40a2-8bba-a14bf57e441b Greece | |
| a20e788a-5a7b-4b8f-9084-bb90c2afdaab Estonia | |
| ba1c967e-c8d0-4378-beb8-c3467e2b1f19 Bulgaria | |
| cfb90d1c-d572-4fd6-81d2-9d5f3402f17d Poland | |
| 5fb1a452-702c-4b58-862c-40e0f03d4200 Germany | |
| 41d07095-380d-4a58-8d4b-124d7b7740ae Sweden | |
| 10df1fbf-2821-46fe-88ad-45ae6a691000 Portugal | |
| d314126f-08af-4818-96b5-3f9c05e90c04 Hungary | |
| 0edea5b6-4ef1-40d0-8f38-6302871707b5 France | |
| 51c22bfe-86fe-4781-97ab-77fda4e2ba0d Germany | |
| e3912ecc-654b-4fa7-a3a5-abe40241b2e3 Netherlands | |
| 82541560-c34b-47c6-b19f-b84bd5089023 Poland | |
| b943e54a-6182-4755-8d65-93538064bd90 Czech Republic | |
| a009922f-8351-4fc6-977a-4343014e3641 Germany | |
| 240510c2-f058-4b8c-ae9e-478dea07e1d6 Finland | |
| b6f176d0-6a98-4989-8fc0-1e6232164fe0 Denmark | |
| 7e9b5f3b-ccb5-49db-825e-3d4f327fbce8 Belgium | |
| ce0e86cc-896f-4e72-83e8-dadab636295e Germany | |
| b4340a1a-2d58-4770-85d4-3d4c39091a9f France | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZACREHAA000A000000XX |
| EAN | 8015644766610 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644766610 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0065 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 244 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |