View larger
1SDA072181R1 ABB E1.2C 1250 Ekip Dip LI 3p WMP
1SDA072181R1
072181
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Managed through part number 1SDA072181R1, this Abb 1SDA072181R1 ABB E1.2C 1250 Ekip Dip LI 3p WMP serves as an air circuit breaker utilized in electrical distribution networks to protect electrical circuits from damage caused by overloads and short circuits. Such devices are standard components in industrial switchgear assemblies, providing critical fault-clearing capabilities and operational safety.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 9a4185ec-6c93-4f84-9273-280c692a990e China
- Simplified SCIP: 95e4836b-20fa-4fca-aeb5-e5e0080e95b7 Denmark
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1CREHAA000A000000XX
- EAN: 8015644760311
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 9a4185ec-6c93-4f84-9273-280c692a990e China |
| Simplified SCIP | 95e4836b-20fa-4fca-aeb5-e5e0080e95b7 Denmark |
| 9fc9452e-9b72-4fb4-be53-5f9586ce2a5c Poland | |
| 8d05b5cc-4195-4177-af91-58376eddcbe8 Poland | |
| f2e9b2dc-7683-43ca-9644-3aaeb3d38162 Bulgaria | |
| 7fb4321b-6848-484c-98a8-2749fc93f907 Estonia | |
| c34f1b76-976a-4340-8510-6d14dcdf35e5 Hungary | |
| ea36e6a4-8c80-47c1-bf15-bc4d5bcb1ed7 Germany | |
| 9f6e5e28-0e34-44fe-9d36-80ce583ff6cd Croatia | |
| 28e7d8c2-eaa3-4888-8896-061ec5d2cb98 Hungary | |
| 6cc637a6-ffd0-447a-a752-99422fe28c4a Greece | |
| 2d15c609-fa74-406e-a4e1-7d552cf3735e Norway | |
| bbcd82a7-dbcd-4ca6-a658-304441b1954b Belgium | |
| f61503a0-1f7c-47fb-b900-fa913309f8ef Portugal | |
| 488b9c59-c6b8-41fe-8eaf-66458dde364f Spain | |
| 7c93b185-89a2-4524-90b2-07a1bfccd599 Sweden | |
| aabfc74e-9bad-4512-8c37-6f1431ca135c Netherlands | |
| 93ea24f9-c738-4c87-be68-04736bcf72f6 Poland | |
| b4f919a8-b617-44b4-a761-ff0235615d4a Czech Republic | |
| 111340c4-1b99-4cb7-85c5-cd611c399478 Germany | |
| ad1e5aab-94dd-418d-9840-9bfe99a2f83a Germany | |
| dd31a99b-8af4-45aa-83be-414b35b7b638 Sweden | |
| 7752c46c-03fd-4711-82dd-14c6cda29fbd France | |
| e89dcf45-ccd3-4194-8588-a910ddb08f55 Germany | |
| bb32a9d7-0dc1-4f47-9108-30c2c3aec8e4 Belgium | |
| c520455e-f3c3-413c-a83d-754690636aa4 Finland | |
| 5b9a9e74-2c3c-40b9-94eb-5cbd38870b4b Germany | |
| f0e1897e-a113-44f3-82d8-0393d57cf5e7 France | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1CREHAA000A000000XX |
| EAN | 8015644760311 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644760311 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 244 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |