View larger
1SDA072145R1
072145
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2360 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 51117947-33e6-4b42-9ee1-5d26530f78b0 Italy (IT) |
| Simplified SCIP | 7517f80a-8bd9-4f67-8475-d766923f741e Germany (DE) |
| 9da6a923-f13e-415b-ab8f-5f8baa781d8f Netherlands (NL) | |
| 672eecff-284f-44f6-a465-e0ac55774002 Greece (GR) | |
| 2966004e-12e9-4521-a80f-0cf520606663 Estonia (EE) | |
| 739d5934-7859-4b8e-adb3-8ad0733e44d0 Portugal (PT) | |
| 90ac74b6-a46c-45d0-ac83-1541cfafaa8a Bulgaria (BG) | |
| 1c4a130f-8ed3-48b6-9730-e4a44fd02c5a Sweden (SE) | |
| 0361a97f-36bb-4d5a-a0d6-d8e2c07b226d Poland (PL) | |
| 48a1abfb-5fa7-4a7b-94d3-25c22ae6ce1a Hungary (HU) | |
| 2b9f9a7e-c1ed-4b7f-a10d-db5925be0fe8 Poland (PL) | |
| a8d2337d-db75-47c8-b747-0bbbce242a40 Czech Republic (CZ) | |
| c944054f-11f4-4a13-adf3-ab95aeb4b8ac Germany (DE) | |
| c3239deb-3d0a-4584-b282-2e9fc956f955 Germany (DE) | |
| 6462d5c3-1ee9-440d-9ddd-984ab99bec8b Germany (DE) | |
| 4c92115d-6f1c-4f0f-a99b-0d8a20268eea Poland (PL) | |
| f7b845ef-d19d-4a2b-b0b4-e5005ee9b411 Norway (NO) | |
| ed0cafd8-3f71-4309-bcc6-8b29974e8ed4 Denmark (DK) | |
| de595a53-3498-4a03-91fa-b017703dbdfd Germany (DE) | |
| e0668c00-bc10-49f7-9ca7-c341f0bf2dbd France (FR) | |
| 19eedc17-ff81-419f-b870-4bb0cfbc2acf Croatia (HR) | |
| 0344fe76-8705-491c-b99b-47d816ea2553 Finland (FI) | |
| 32597214-06d5-42f2-8d6f-b8d2ade07584 Belgium (BE) | |
| 24f06968-4206-475b-991d-a506d7ca4cb2 Sweden (SE) | |
| 274b5ea6-57f7-4d23-99f2-55d3583a63c4 Belgium (BE) | |
| c35cbb4a-419b-4861-a210-2358a89b42d5 Spain (ES) | |
| d9367f52-af05-412d-af45-af0ace1ab756 France (FR) | |
| 1c7123c5-7f88-4d78-accc-e1e1b0eeae89 Hungary (HU) | |
| Ordering | |
| Order Code US and Canada | Z1CQEGAE000A000000XX |
| EAN | 8015644759957 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644759957 |
| Additional Information | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3 |
| Power Loss | 156 W |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Current (In) | 1000 A |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |