View larger
1SDA070794R1 ABB E1.2C 1000 Ekip Touch LI 3p F F
1SDA070794R1
070794
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
ABB E1.2C 1000 Ekip Touch LI 3p F F is an air circuit breaker engineered to protect mid-to-high capacity electrical distribution networks. Industrial facilities depend on these units for reliable overload clearance and fast short-circuit interruption.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: e3fce228-a061-416d-8bfc-29ba9731deda Italy
- Simplified SCIP: b2a81a6c-b594-4542-b508-4354c1449c2d Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1CQEGBD000A000000XX
- EAN: 8015644746445
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | e3fce228-a061-416d-8bfc-29ba9731deda Italy |
| Simplified SCIP | b2a81a6c-b594-4542-b508-4354c1449c2d Germany |
| 49d1a7bb-7e47-4216-8d23-e0ea1cc85c14 Poland | |
| 695b73a9-4b53-4697-9884-7c8843ca1bfb Poland | |
| 07b5c656-1203-4dbe-a69d-0917e0b14beb Sweden | |
| ee1abba1-161b-434d-a274-51aade8c813d Portugal | |
| 562bc99d-fa7b-4451-a2fe-12b6865aee35 France | |
| fd42eae6-371c-4cf7-8e7f-3251a3fa3a31 Croatia | |
| 56cf7cfb-8335-443a-b047-d34c68b09cb5 Hungary | |
| d84b829c-e21e-47bc-a80d-9eae74880c77 Estonia | |
| f7b89e82-d8e8-460f-bf39-f76b88153925 Germany | |
| 8a9993b2-c2b6-4dc3-9922-d0a045bec3c1 Denmark | |
| 2cd7803d-55e3-4b24-8f70-6757bd7fc36d Germany | |
| f1057f60-99ad-4628-aa34-64c79a645eb6 Finland | |
| 4893b9e5-1a5a-4260-8e18-d082c70e68b2 Greece | |
| 0831eba8-a81a-4736-9407-ab3722471aaa France | |
| 865cdde3-2f98-4542-aea8-7e29e15a5a8b Netherlands | |
| 65fcca67-65dd-4eba-96d9-f58d12321d30 Sweden | |
| b45f5ac6-cf11-4dde-b883-39e81b73af4c Belgium | |
| 1288d69b-442b-406a-85f4-1702998151c5 Bulgaria | |
| d843e7b7-5a8b-461f-8a6d-9ea8fd44deaf Germany | |
| 19a0b70e-43e0-4313-8595-15c71a65f196 Germany | |
| fedcf05c-dec8-4d55-ac71-85e3be3d2548 Poland | |
| fdb6f62d-bcef-462a-bfab-256bb296b434 Norway | |
| a214da95-ff6f-4d49-98dc-ed8f02fc64ce Hungary | |
| fb233997-bfdd-4a51-a6f8-681500b123fa Czech Republic | |
| b88667e4-3855-4295-b449-45c4a5b7b0cc Belgium | |
| 74364361-c142-424f-9f50-b96ad9f28543 Spain | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1CQEGBD000A000000XX |
| EAN | 8015644746445 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 14 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644746445 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 78 W |
| Rated Current (In) | 1000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |