View larger
1SDA072772R1 ABB E1.2C 1000 Ekip Dip LSI 4p WMP
1SDA072772R1
072772
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A withdrawable four-pole Abb 1SDA072772R1 air circuit breaker provides safe isolation and robust protection for complex power setups. Engineers specify withdrawable breakers in critical infrastructure where easy maintenance and rapid replacement are essential. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360 ...
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 285b5e99-1180-4b54-b6c9-4f35fb63d4ff China |
| Simplified SCIP | c033ddf8-29e1-4ec2-961b-c365f49abff4 France |
| ec26f71b-8533-48ae-91fc-3acacba080e4 Portugal | |
| b5f87b45-f3cb-4777-a6e3-a70d7449a5a2 Sweden | |
| 26300641-ef93-48cc-b181-189f39913648 Belgium | |
| 9885dbd1-9a78-4cbb-b5af-369f87d776ff France | |
| 1d9cd618-70ea-4278-a509-d846d49099ab Germany | |
| ed5ac6cb-ab37-4ba8-9efb-8e6bd46a4a3b Finland | |
| 421ec9b7-b831-49e5-8937-4fd398bfdda6 Germany | |
| e14259b5-82e1-420f-b74c-4870287002ff Denmark | |
| 04e9ae66-0bf9-46ee-accf-1b791b18e3ea Germany | |
| 4f98d2a1-ecf8-4a74-b08f-828c362e82e5 Norway | |
| 2e844ed9-f1d0-4c28-82f7-146778d598a9 Hungary | |
| 68df836d-6745-41d1-8378-616c271db4b9 Greece | |
| ddb8fc13-8219-42fc-962d-a5efc6a96699 Poland | |
| 0655d60a-80c6-4cc6-b561-ba63e8d86321 Bulgaria | |
| 13f16324-458b-477d-8a1a-734f1d49365e Estonia | |
| ad1e2682-a1f7-4c21-8f9f-5590ed9e34bc Belgium | |
| ec6ff6f8-4fcb-4966-ae3a-3aa0f4459142 Poland | |
| aeb7e4e4-874e-4b43-a780-b061655e33cb Spain | |
| dabb2a3a-9cd0-47b7-97ac-1fed1c7375a0 Sweden | |
| bf04b529-527e-47f4-8e0d-5fa78d0d3446 Germany | |
| 4aba4228-45fb-435f-b1d4-e7d39256e427 Croatia | |
| 7eeecaeb-47cd-4c54-b72b-893456fe1f22 Hungary | |
| e97fda50-9ddb-4c2c-9276-1b2e822a7549 Germany | |
| 25acef18-9b59-4202-a407-ee916951d8b6 Poland | |
| e5e852c6-2a55-4013-b51d-9fcb1999a3f7 Netherlands | |
| 1aa4840d-17e3-42cd-81ca-197848e018e5 Czech Republic | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZACQEGAB000A000000XX |
| EAN | 8015644766221 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644766221 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0065 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 156 W |
| Rated Current (In) | 1000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |