View larger
1SDA072096R1 ABB E1.2B 800 Ekip Touch LSIG 3p WMP
1SDA072096R1
072096
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB E1.2B 800 Ekip Touch LSIG 3p WMP functions as a sophisticated air circuit breaker equipped with advanced electronic trip units, designed for precise energy management and fault interruption in heavy electrical switchgear. Such withdrawable circuit breakers are commonly installed in industrial power distribution networks to protect transformers, generators, and primary feeders.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: abc669ac-3b5d-4f21-84e8-488477b332c2 Italy
- Simplified SCIP: bce732c4-97d5-4709-867e-80c3102885a1 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1BPEFAF000A000000XX
- EAN: 8015644759469
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | abc669ac-3b5d-4f21-84e8-488477b332c2 Italy |
| Simplified SCIP | bce732c4-97d5-4709-867e-80c3102885a1 Germany |
| 43d28e25-c632-46ee-8d00-81868a400437 Hungary | |
| 6ca36348-ddef-4cd2-84d2-da116ec7f29b France | |
| 4319743c-a28f-4eb0-b000-6950752e3e25 Norway | |
| 1fca46bf-659a-4eee-abe6-a002add46e9d Hungary | |
| 522b3efa-a190-4b9b-a385-3459c2bacbb0 Denmark | |
| b9271c38-82f6-4241-8a43-4de9e3649979 Germany | |
| 9dd85ec2-92c3-4282-a200-2d65d2e847e3 Belgium | |
| 00f6ca62-a7b6-456b-b525-5a256f2e507a Germany | |
| 732a1cab-59c4-4ed1-b858-506e1f1f4f14 Croatia | |
| bfeacbef-c859-4762-b40d-45f99d42a990 Germany | |
| 221bb903-a3ac-421f-8e27-234f23f8d3f0 Germany | |
| c119c91b-ddc4-4dc3-9cfc-48c6f0c7db35 Sweden | |
| ca6e4338-8d9d-45e9-ae70-abd95835a15e Netherlands | |
| 7ce91782-2b2d-4527-8d82-311144f9e122 Estonia | |
| 368ec88e-04c4-4c23-8984-6836f86ac394 France | |
| 3e9c44e4-5aed-4716-b09d-b0cd0cfa7c07 Greece | |
| 50cfe2b4-8e25-4a38-9997-f396414c26ea Finland | |
| c56a94c5-f9d3-469d-b6bd-c9f69a4c41c0 Poland | |
| bf47301d-13ef-496c-83ae-f99656fc4cf0 Belgium | |
| 240db5a9-f9a3-459a-9237-d0d11d4b03fb Spain | |
| ce989e21-f4e3-4464-9fa9-596427344a7a Poland | |
| 90e18455-0d37-4650-9816-c9c485d74598 Poland | |
| dfd7ba56-361c-4740-9070-509fef012d36 Czech Republic | |
| 9367de58-0801-48a0-aa9e-20eaa0199f19 Bulgaria | |
| e25c6b08-f452-47e1-9ae7-850401a069f3 Sweden | |
| 0b61ffca-f801-4d56-a0a3-54a275a8aa5a Portugal | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BPEFAF000A000000XX |
| EAN | 8015644759469 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644759469 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 100 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |