View larger
1SDA072096R1
072096
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | abc669ac-3b5d-4f21-84e8-488477b332c2 Italy |
| Simplified SCIP | bce732c4-97d5-4709-867e-80c3102885a1 Germany |
| 43d28e25-c632-46ee-8d00-81868a400437 Hungary | |
| 6ca36348-ddef-4cd2-84d2-da116ec7f29b France | |
| 4319743c-a28f-4eb0-b000-6950752e3e25 Norway | |
| 1fca46bf-659a-4eee-abe6-a002add46e9d Hungary | |
| 522b3efa-a190-4b9b-a385-3459c2bacbb0 Denmark | |
| b9271c38-82f6-4241-8a43-4de9e3649979 Germany | |
| 9dd85ec2-92c3-4282-a200-2d65d2e847e3 Belgium | |
| 00f6ca62-a7b6-456b-b525-5a256f2e507a Germany | |
| 732a1cab-59c4-4ed1-b858-506e1f1f4f14 Croatia | |
| bfeacbef-c859-4762-b40d-45f99d42a990 Germany | |
| 221bb903-a3ac-421f-8e27-234f23f8d3f0 Germany | |
| c119c91b-ddc4-4dc3-9cfc-48c6f0c7db35 Sweden | |
| ca6e4338-8d9d-45e9-ae70-abd95835a15e Netherlands | |
| 7ce91782-2b2d-4527-8d82-311144f9e122 Estonia | |
| 368ec88e-04c4-4c23-8984-6836f86ac394 France | |
| 3e9c44e4-5aed-4716-b09d-b0cd0cfa7c07 Greece | |
| 50cfe2b4-8e25-4a38-9997-f396414c26ea Finland | |
| c56a94c5-f9d3-469d-b6bd-c9f69a4c41c0 Poland | |
| bf47301d-13ef-496c-83ae-f99656fc4cf0 Belgium | |
| 240db5a9-f9a3-459a-9237-d0d11d4b03fb Spain | |
| ce989e21-f4e3-4464-9fa9-596427344a7a Poland | |
| 90e18455-0d37-4650-9816-c9c485d74598 Poland | |
| dfd7ba56-361c-4740-9070-509fef012d36 Czech Republic | |
| 9367de58-0801-48a0-aa9e-20eaa0199f19 Bulgaria | |
| e25c6b08-f452-47e1-9ae7-850401a069f3 Sweden | |
| 0b61ffca-f801-4d56-a0a3-54a275a8aa5a Portugal | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BPEFAF000A000000XX |
| EAN | 8015644759469 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644759469 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 100 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |