View larger
1SDA070746R1
070746
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | a9ea699c-1fd1-412a-acc2-58c9e347e674 China |
| Simplified SCIP | c760ddfa-d0cd-40c3-81f1-60cd9f38a3c8 France |
| f3df0c7e-b722-461a-b943-466139d3d882 Sweden | |
| f4e8026e-7a8f-43ef-818a-6c67d1f58c9c Germany | |
| 8b64314d-b316-419e-a361-00d9de9ff33a Hungary | |
| 51112042-6242-42ca-84cf-11f74057a514 Belgium | |
| 34373516-ccb3-467c-b8e2-63ff554cde54 Germany | |
| 73f63322-35fe-4652-8e79-02c9fc933a41 Croatia | |
| b546a013-cf77-4014-b89b-27fbd1021408 Greece | |
| f6648673-9420-4638-895f-6cae0a1eb5af Norway | |
| 3a262841-007e-408a-b092-d409cac7ebe6 Spain | |
| 40237a11-1170-4bdd-b9fe-bb9f9e83d963 Portugal | |
| f4ad5a2d-f8d6-4bd9-bed8-03674a2b49e3 Hungary | |
| 5745c591-88ee-4c42-b5f1-bd9e4248ddf5 Estonia | |
| 598dfec2-9137-48f0-a06d-9dc96c81ce48 Poland | |
| c439b039-dd9d-4e76-93e5-2c7c43334d21 Poland | |
| d07ad267-6978-47f0-b23e-d7d23e1c7dc4 Sweden | |
| 8266af1f-be32-4cb0-8861-063cd98e571a Bulgaria | |
| 9f297a95-d6b2-4463-8ce2-8585a8214df4 Czech Republic | |
| df2d94fe-b0e0-4eb9-a844-186edd7f255e Germany | |
| d69b7b85-27bd-4cb0-988d-cc4ef236cfd5 Netherlands | |
| 3afebe4c-1140-4fdf-b47f-5bf6bd5b0507 Poland | |
| 150b33bf-8124-4581-8f88-0f12a22bcaa7 Germany | |
| 40513dee-d962-4e64-bd3a-6f2ed6bc0da0 Finland | |
| b5427601-7f10-4f33-8458-df1b579d395b Denmark | |
| ea5f2346-3866-4ba9-ab90-6a37a53e83c7 Germany | |
| 644e0c8c-fed7-48ce-a4ae-5331b4c250ed France | |
| 53e8a64d-961b-449a-81e3-414a8d6e51cd Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BPEFBF000A000000XX |
| EAN | 8015644745967 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 14 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644745967 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 50 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |