View larger
1SDA070745R1
070745
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 56d12bec-f5e3-4f57-bbec-5269600acf59 Italy |
| Simplified SCIP | 96964b84-a4e6-4467-8c67-69456f06feb7 Croatia |
| 294de36e-6215-4633-8bac-504c8807c6ce Netherlands | |
| e20a5212-561c-45eb-8f7b-94e1e9e306f1 Poland | |
| 0d5952db-2ce9-43eb-8539-ccb5b5905716 Poland | |
| 812f5367-7c8d-4ac6-b2da-2360116898f5 France | |
| 20ddcd85-1f4f-4949-9770-90f3e4048b73 Greece | |
| c8571291-831a-44c2-a0b4-3e6285e98cb4 Hungary | |
| 923fed77-1953-4822-a1ac-7dbabef1ae94 Estonia | |
| 4e01a339-bb96-4965-a2f8-c2f0053b5ced Spain | |
| ae28f5dd-4d82-4e79-a762-bd74bd38cb7b Czech Republic | |
| 4f539d54-ec45-4ff2-ba4c-abd3b8c7f975 Bulgaria | |
| ad5bbcdc-f2a1-4200-bef8-3641023551bd Germany | |
| 4ad27d24-7bd0-4145-a164-0f79f19ca928 Sweden | |
| 22c78001-48f1-4ee9-8568-c0b5286419a7 Poland | |
| 0a147a56-1989-40b8-8555-47fe574d7340 Sweden | |
| f326ee11-b80b-45ce-8acf-49fa7b0f3b3c France | |
| 13926f9c-5696-4ee6-b1f3-de4cbd0af804 Portugal | |
| 7f2c50dd-3272-43ea-b077-1b74c6670920 Belgium | |
| e42f534e-bea1-4f0d-bfa3-f0834fcecb3f Germany | |
| 4dfc2d92-7f01-4731-b6a9-7069829c88a1 Belgium | |
| 99dfe7d3-fd2d-4e04-a8ca-3c2b20556520 Norway | |
| eb14448f-12db-400f-86bc-a3c8906e2490 Denmark | |
| c471ba73-42f7-41c5-bbc9-7a9b7925184a Germany | |
| 5cd25125-6d62-45f9-abb4-3a036268c01a Germany | |
| f24a4e4b-5db2-4da5-927c-4e80f409012e Finland | |
| d6c7e032-e500-4694-8d8c-0b9300f7dd5a Germany | |
| c3590956-5689-4c3a-a438-cab3e34312e8 Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BPEFBE000A000000XX |
| EAN | 8015644745950 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 14 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644745950 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 50 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |