ABB 1SDA070750R1 1SDA070750R1 ABB E1.2B 800 Ekip G Hi-Touch LSIG 3p F F View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SDA070750R1 ABB E1.2B 800 Ekip G Hi-Touch LSIG 3p F F

1SDA070750R1

070750

ABB

1 Pcs.

E1.2B 800 Ekip G Hi-Touch LSIG 3p F F

Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A withdrawable air circuit breaker, represented by the 1SDA104634R1 ABB E6.2H/E9 6300 Ekip Touch LSI 3p WMP from Abb, is engineered for high-voltage power networks to safely interrupt heavy load and fault currents.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Rated permanent current Iu (EF001389): 6300 A
  • Rated voltage (EF003977): 900 V
  • Overload release current setting (EF002336): 2520.0 A
  • Adjustment range undelayed short-circuit release (EF007131): 9450.0 A
  • Integrated earth fault protection (EF007296): No
  • Type of electrical connection of main circuit (EF006819): Connection at separate chassis part
  • Device construction (EF008240): Built-in device slide-in technique (withdrawable)
  • Suitable for DIN rail (top hat rail) mounting (EF007250): No
  • DIN rail (top hat rail) mounting optional (EF008904): No
  • With switched-off indicator (EF007006): Yes
  • With integrated under voltage release (EF001390): No
  • Number of poles (EF001391): 3
  • Position of connection for main current circuit (EF006671): Connection at separate chassis part
  • Type of control element (EF006976): Push button
  • Complete device with protection unit (EF008906): Yes
  • Motor drive integrated (EF006697): No

More info

▲
ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2360
Environmental Product Declaration - EPD9AKK108468A1900
9AKK108468A3028
Extended Product LifetimeLifetime Extension Services are Offered
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
Environmental
Environmental Information9AKK108467A6707
Ordering
Order Code US and CanadaZ1BPEFBQ200A000000XX
EAN8015644746001
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width210 mm
Product Net Height296 mm
Product Net Depth / Length183 mm
Product Net Weight14 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width270 mm
Package Level 1 Height350 mm
Package Level 1 Depth / Length330 mm
Package Level 1 Gross Weight16 kg
Package Level 1 EAN8015644746001
Additional Information
Product Main TypeSACE Emax 2
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
VersionF
Technical
Connecting Capacity500 mm²
Current TypeAC
Electrical DurabilityUe =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Mechanical Durability20000 cycle
60 cycles per hour
Number of Poles3P
Power Loss50 W
Rated Current (In)800 A
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)AC 1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)100 %
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 42 kA
for 3 s 24 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
Rated Uninterrupted Current (Iu)800 A
Rated Voltage (Ur)690 V
Recommended Screw DriverM12
ReleaseEkip G Hi-Touch LSIG
Release TypeEL
Short-Circuit Performance LevelB
StandardsIEC
Sub-typeE1.2
Suitable for IT NetworksYes, 690V
Terminal Connection TypeFront
Certificates and Declarations
Data Sheet, Technical Information1SDC200023D0209
Declaration of Conformity - CE9AKK106713A5546
EU Data Act Compliance Declaration1SDH002560A1001
Instructions and Manuals1SDH000999R0002
Instructions and Manuals (Part 2)1SDH001316R1002
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)4926 >> Air circuit breakers
Object Classification CodeQ
UNSPSC39121615
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.