View larger
1SDA070743R1 ABB E1.2B 800 Ekip Dip LSIG 3p F F
1SDA070743R1
070743
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB E1.2B 800 Ekip Dip LSIG 3p F F is an air circuit breaker engineered to protect heavy electrical distribution systems from overloads, short circuits, and ground faults. This unit interrupts high fault currents reliably, safeguarding critical infrastructure in industrial settings.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 69f19a67-692b-48b9-b639-4a8f477a884c China
- Simplified SCIP: 37fec68b-64c3-4ec1-9b54-430c63b372c7 France
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1BPEFBC000A000000XX
- EAN: 8015644745936
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 69f19a67-692b-48b9-b639-4a8f477a884c China |
| Simplified SCIP | 37fec68b-64c3-4ec1-9b54-430c63b372c7 France |
| 1c9679ec-c072-4dd1-aeff-66b433e68af5 Sweden | |
| 607d1819-6a33-4033-9e26-f6f5905b5be3 Poland | |
| 6950978d-3298-4389-a073-1365db39e2e8 Greece | |
| 1589778d-a316-48b8-95d1-e8a6db294d7e Norway | |
| 7182ebd1-e2c3-4ef0-b758-faa21a6b1da1 Germany | |
| 182c0a75-ab6f-4ca8-97fb-abf5974e511f Hungary | |
| 51f8e188-6786-484c-8e66-19b98824f8c9 Belgium | |
| 186e0be7-bce7-4185-aa5b-18ce6b74e6ff Germany | |
| 73f21f38-5122-48d0-b4f4-6876686a96a8 Bulgaria | |
| 951074cc-f0cd-4003-9f14-f191c09331ee Estonia | |
| d211fef2-41de-4218-993a-b4a9fbf397de Poland | |
| 5e3e3440-1fcd-4b9c-954d-6f84aebab4ea Hungary | |
| 185434bf-87bf-4823-a6d4-06eb54017ccb Spain | |
| cc2fd475-3a68-4658-b833-dc380df2b117 Finland | |
| da78afc8-c11f-42de-af02-8c76c20f1d4c Germany | |
| f330a36b-b9bf-4ec5-a678-e537cb286346 France | |
| bf0a7a09-7250-4bd9-a277-b67608126e98 Germany | |
| 4b8dc0c8-81d8-4ed1-8b82-285cd55bcbbf Denmark | |
| c92a6a26-79dc-4bb1-a625-e10652ee8448 Portugal | |
| 396ecfaf-9909-45b7-8b36-ebe6d02a9c85 Sweden | |
| abcfbe99-02db-41a1-ae64-92004faf685a Croatia | |
| 736fa917-93da-49e2-adf2-1e53eaf9eb03 Belgium | |
| 892b18df-4c92-4de3-b9b5-a852f1147693 Czech Republic | |
| e9db7785-2a0c-4d61-b3af-15f297d1bc0c Poland | |
| 91210209-f26a-42f8-9b9f-9a7ace431fe8 Netherlands | |
| 43e2b211-9910-4e5f-9d32-cea1aa7f6dff Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BPEFBC000A000000XX |
| EAN | 8015644745936 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 14 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644745936 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 50 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |