Request QuoteProduct Overview
Air circuit breaker 1SDA072091R1 by Abb offers robust electrical protection for high-capacity industrial electrical infrastructure. Such breakers are deployed in main switchboards to safely isolate sections of a facility during overloads or short-circuit events.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 097343df-bbba-4ce8-ac3f-ab62f6a05620 India
- Simplified SCIP: 2980f5d0-abb9-457d-b763-4ba00867b224 Poland
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1BPEFAA000A000000XX
- EAN: 8015644759414
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 097343df-bbba-4ce8-ac3f-ab62f6a05620 India |
| Simplified SCIP | 2980f5d0-abb9-457d-b763-4ba00867b224 Poland |
| 2b91f76f-0045-4ab8-95ff-4be3062f2d14 Germany | |
| c178b018-8239-4099-b637-8b0492d59dc2 Finland | |
| 6bfb8e4d-3e93-4030-8218-562007ad40d6 Poland | |
| 7c1b2248-b403-4149-a5e9-4c4c13cc72c8 Czech Republic | |
| ac6ef6e1-99da-421d-92ad-e9837342213a Croatia | |
| 33e5164a-fd01-498c-88b7-f5b515e562a9 Hungary | |
| 0bf67222-91d2-431b-b66b-b5ed08cb346f Netherlands | |
| abb04e4e-d5b8-400c-842e-07ab7b007747 Hungary | |
| 4085dfa5-2cf9-4087-8f7b-3fc1484466af Belgium | |
| 9a4bd036-5995-45c2-a2d4-71fb56b0bb30 Spain | |
| f54f28af-70b1-4db6-b77d-7c1f42a7d496 Germany | |
| 3357594b-e4d6-49f8-a200-8b77fd670482 Germany | |
| 85811f32-29e9-4703-921b-d9002c6df0cb Sweden | |
| 6b4a62fd-ae34-48a2-8bd6-6b31bc18a6fa Bulgaria | |
| 1a7d8e9b-9653-4c92-8188-5bc37ac695f4 France | |
| 96822d14-eec1-4102-ac95-f09cd8933bfa Portugal | |
| e11126d4-176e-401b-aa27-f6b43ccfa140 France | |
| 07637d43-29a2-44c8-9762-0b35fa343991 Sweden | |
| acc0389a-927c-4de3-b373-d0c5b24e3866 Poland | |
| 2113d087-ca50-48f5-ba90-759aa5e7d579 Greece | |
| c9470b07-54e4-4d12-90cd-bd38661fdf3c Estonia | |
| 2ad4230f-3aa1-41c3-8619-04f262454165 Denmark | |
| 66b2a153-c500-4dfd-bffe-6b6e77ffa9ec Germany | |
| 61b9ea58-fd9a-481a-b940-3f22fb2bbdd4 Norway | |
| 641c545d-2d00-452c-b707-02a1d3480a0c Belgium | |
| f0950393-8819-4dad-8ccd-df36d507957f Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BPEFAA000A000000XX |
| EAN | 8015644759414 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644759414 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 100 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |