View larger
1SDA071339R1
071339
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | a0e30b14-8eb1-470d-a58d-1384b140d7e0 Italy |
| Simplified SCIP | 4a33bf74-6cd9-485a-8d38-ba63568039f3 Germany |
| 0dfbc28f-4e2e-4a35-baab-59c1a80d25bb Hungary | |
| 4f2cebba-413a-4ee2-bff4-1eb57f44d7d5 Spain | |
| 5ca8c178-42c4-41b2-a6ec-aa04ee41ad36 Belgium | |
| b47c550c-3b80-47f7-af98-3a3fe45ac5f3 Sweden | |
| 809e2bfb-423c-46e4-bb31-05428f7b1e41 Portugal | |
| d7741677-e772-4b2b-87df-434f69141234 Poland | |
| 533759b9-27ab-413b-88a1-88e3a9483fb1 Poland | |
| 88d74197-0ca3-4dd8-8a1e-8ffd54152a97 Czech Republic | |
| 88989f7e-160d-4824-8f9f-8be252e1aeaf Hungary | |
| d7dc7e2f-1953-4bbd-a083-f8b1d323c108 Poland | |
| b3aff4c5-0937-454b-9e2f-3348f9539e11 Norway | |
| 4140686d-383b-4cd2-a0d0-8aaa27ab0fda Greece | |
| c1dbd41c-377e-41e1-9b93-cdfe9f88fecb France | |
| c51885fb-4033-47c7-8aa3-712c1d3bd3f3 Finland | |
| 1d6937c2-0813-4c41-9fe1-27771b19f9dc Netherlands | |
| 1a2d3932-40ce-4a07-8df1-cacef21669d8 Estonia | |
| b506aabc-644d-473d-843c-b76adce48a2d Sweden | |
| 9d02d73f-ea09-414e-9245-f4e14f23bb15 Denmark | |
| d034636a-b026-40cb-810a-e5d3464bd08a Germany | |
| 57e3c332-8bbd-4f43-a64b-27ece965e781 Germany | |
| 875920ca-0100-401e-a219-07bb957caece Belgium | |
| f734b5b5-b608-493d-a4f9-61d7e87ea760 Bulgaria | |
| bb43253e-4b6b-4475-ac10-f610b303d60b Croatia | |
| 6bf8adce-b8ce-4013-9129-963ffe2c3842 France | |
| 8c000b08-82f3-40b9-b02a-d4d653e9c20d Germany | |
| 1d982ae1-a525-41ee-9a8b-9221870864f9 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZABNEEBK200A000000XX |
| EAN | 8015644751890 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644751890 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 400 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 31 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |