View larger
1SDA070703R1 ABB E1.2B 630 Ekip Dip LSIG 3p F F
1SDA070703R1
070703
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The 1SDA070703R1 ABB E1.2B 630 Ekip Dip LSIG 3p F F is an air circuit breaker utilized for high-capacity electrical distribution and main switchboard protection. It manages heavy electrical loads and clears complex fault scenarios to secure industrial infrastructure. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
- Simplified SCIP: a16503c8-c993-4d7a-9277-704db1bb451b Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1BNEEBC000A000000XX
- EAN: 8015644745530
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy |
| Simplified SCIP | a16503c8-c993-4d7a-9277-704db1bb451b Germany |
| 8b03cfe9-7657-4778-acb1-5e456af5c76a Denmark | |
| 64831dac-5718-413a-b2dd-c2a16236b94f Sweden | |
| 7635dc57-155c-4b3b-8d16-637f7a9317ca Estonia | |
| bf55e5c1-47fb-4603-bc85-150f2bba6810 Netherlands | |
| 8d8d3917-aca7-4875-98c5-244d35793f56 Bulgaria | |
| cc5cb3c7-f20f-4e57-a699-41c96b5a1eef Norway | |
| 560d9c18-bf6e-4a6e-b95a-82f0dcbd0d2c Sweden | |
| 55ebef71-4502-4891-8767-e9a15ef09392 Poland | |
| 7e9377e0-b60f-471e-982f-360fb85b51c6 France | |
| 5b96a5ce-08d7-4ea3-9d9d-b2ed25c73f5d Netherlands | |
| 7f3be359-1216-4d35-b9d4-eab9cbb290fd Poland | |
| 13fc1439-00ad-45bf-abdd-5ede1ce20a7d Netherlands | |
| de9a0119-6bd3-4d97-a5d3-1e74d280ccf7 Netherlands | |
| 08ff7a7d-f7c4-4a97-ab1f-2f60e52ccc4e Germany | |
| 18044daa-d0c0-4608-bafb-451bb9d8efe4 Croatia | |
| de6447a0-df24-4a20-8466-f5f11a930a19 Finland | |
| 5ede7a36-3b83-4497-b7e0-ef217691ad89 Czech Republic | |
| f49fce99-7561-4c32-880a-478431f7efd7 Greece | |
| e5eed5bf-546a-4db4-a608-d4b83c43c056 Poland | |
| f40ef067-0a7a-4928-831d-6affa0d2f0c7 Germany | |
| 8ad28a13-de77-4592-95fd-897a501569c8 Germany | |
| 05702ea0-ab49-475f-8469-3cf48dabeb77 Portugal | |
| 1ac41cb5-8851-4d50-97e5-9a58e2df1d99 Spain | |
| 6e3f01fd-be03-4be8-9d80-b02a9984a4e1 Germany | |
| 1c74a6dc-b960-484a-a4e4-4114d79c6a3d Netherlands | |
| a940f727-3880-42c1-bdc0-d5e1d498ddaf France | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BNEEBC000A000000XX |
| EAN | 8015644745530 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 14 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644745530 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Connecting Capacity | 400 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 31 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |