View larger
1SDA072051R1 ABB E1.2B 630 Ekip Dip LI 3p WMP
1SDA072051R1
072051
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Offering modular and reliable electrical isolation, this 1SDA072051R1 ABB E1.2B 630 Ekip Dip LI 3p WMP air circuit breaker protects low-voltage distribution lines against overcurrent events. Such withdrawable breakers allow for fast maintenance swaps and secure circuit isolation in large-scale power setups. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: aa56abb8-60e7-4510-b053-b0a9dd8ea390 China
- Simplified SCIP: a0ce3c7e-2f6f-4439-8c06-c1ee0a02615e Czech Republic
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1BNEEAA000A000000XX
- EAN: 8015644759018
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | aa56abb8-60e7-4510-b053-b0a9dd8ea390 China |
| Simplified SCIP | a0ce3c7e-2f6f-4439-8c06-c1ee0a02615e Czech Republic |
| 0809f92e-a8cb-4947-ae7d-d68b4198e30f Sweden | |
| b970e512-1939-4c4e-abd7-0c8c3ed6663f Belgium | |
| 4921d69b-83fc-4f50-bf58-4108001ed694 France | |
| 93636c04-5621-4461-9385-f3b5507bfca5 Germany | |
| 73a742f5-786b-418c-91a0-d679ae79b311 Denmark | |
| 5f21ee1f-6a86-4951-b40e-3ed4a8537df5 Germany | |
| 0a765cd9-90fa-456a-97ff-eab285535631 Finland | |
| fd8ea0b2-0ce3-4096-9d1f-2dd6fd36e80b Germany | |
| 4f2c2e13-4d44-4ac0-b6bb-b7f1d7ead980 Croatia | |
| 9854d4fd-5dc6-48cf-aa82-76faf1a736dd Hungary | |
| 119f374f-9c18-49e7-bc41-37b0bf24ae2f Belgium | |
| 02e4773f-da7a-40ec-85d1-801388fabfa1 Spain | |
| dd13444e-5192-48d3-bea4-e4949a69998f France | |
| 677b8e2c-78dc-4cb7-bd11-baf9f25527dd Greece | |
| a9c5e468-058d-48d9-81ef-ea94ee476815 Norway | |
| 2ff16365-4fc3-4e8c-abac-dd19364a3022 Poland | |
| 99d72aef-4307-4dc4-b110-55576bb9bde8 Hungary | |
| 0bb68916-49e5-4700-923e-76055c7eeed0 Estonia | |
| 7d518832-5fc4-4fed-b4f5-5d6a3f8eadcf Poland | |
| ee8cb220-9858-4185-a090-a0cc2c7e43a5 Germany | |
| b11b8b69-5b93-4655-98f7-899535c988c5 Bulgaria | |
| d44e0dd7-9067-407b-9efb-bde76df4a026 Portugal | |
| 69537700-3b39-413c-b4be-2fb8782a873c Sweden | |
| 61804d3d-f9e7-4bd4-9d90-b7a9e98f1a23 Germany | |
| 05a05609-fe26-4dfb-a26e-e37298c761a2 Poland | |
| f958de55-9a6f-4a8c-880c-b5d6c99f66eb Netherlands | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BNEEAA000A000000XX |
| EAN | 8015644759018 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644759018 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 400 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 62 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |