1SDA071493R1
071493
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | bd0b90ba-5ddd-403a-a313-c046b7f55020 India |
| Simplified SCIP | 24241e6a-ec1b-4ae7-90a0-11bc9c5c8500 Portugal |
| 2359817a-62ec-4eb3-bc3c-a4531ebb5c30 France | |
| 4565130f-a4f9-4344-a9dc-d7ac54e72a80 Germany | |
| d693f36e-df91-4733-b68c-aa31185434fa France | |
| 07605133-a95c-47d6-a081-304c5170d0a3 Germany | |
| 59c25a64-d39d-4844-ab58-20454223ac15 Sweden | |
| 820e315e-3442-4467-abb3-a3fcc7fc3389 Bulgaria | |
| 220c2b2a-9eb3-420c-ad11-69b5ac053211 Greece | |
| 0dfbc79d-a94c-4c20-8fd6-ede33a9403ff Poland | |
| e69f2751-ffb4-47e3-a27f-561ef97a3516 Sweden | |
| b1902008-8964-4cf6-b529-3b1ff7dd8f57 Estonia | |
| 4963f5b2-ffbf-441e-888e-f98c58e22644 Germany | |
| bd4f0c1d-d096-45c9-9599-bf5976cf2745 Denmark | |
| 15aa9444-9dac-4783-9a28-b1384a41dd45 Germany | |
| 35979377-f355-4431-89f8-2b0ebc4e0fd3 Norway | |
| 83a787b2-2e86-486a-b114-170de0a78e5e Belgium | |
| 60cd67f0-92e3-48cc-963c-752dbbe59c58 Finland | |
| 1937cd34-a906-46f0-a434-5106aa673ac7 Germany | |
| 9c190d94-c1e0-42a7-9a39-66e1f544155f Poland | |
| 28100924-b0db-4104-a2f9-3e19887659d4 Hungary | |
| 4f66cc23-e46d-403c-9a92-4888abbbf2bc Czech Republic | |
| e856cb55-8dc0-4c73-b075-3f6a2819d8a4 Croatia | |
| 705cdd46-6ae7-48a0-831b-4ce1306f5760 Hungary | |
| a54c5271-6ec7-4408-9879-c2a7b20915be Netherlands | |
| 1960842d-7c84-41b0-86a2-31f3c35a299c Poland | |
| c79b4575-40b9-426b-98cb-ac9ed339f73e Belgium | |
| 5648c6c9-ff33-46c3-9d09-f08b8ce6d0ba Spain | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZABSEJBC000A000000XX |
| EAN | 8015644753436 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644753436 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 1200 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 3000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 201 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |