View larger
1SDA070863R1 ABB E1.2B 1600 Ekip Dip LSIG 3p F F
1SDA070863R1
070863
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This ABB 1SDA070863R1 ABB E1.2B 1600 Ekip Dip LSIG 3p F F is an air circuit breaker engineered to protect heavy-duty electrical distribution systems against overloads and short circuits. Such devices provide critical fault isolation and manual or automatic switching capabilities in industrial switchgear installations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: b5ebe30c-350b-438b-b2e2-4242f63715c2 Italy
- Simplified SCIP: 8acdaa88-d2c8-4599-8b3b-bcaaba742e4b Norway
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1BSEJBC000A000000XX
- EAN: 8015644747138
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | b5ebe30c-350b-438b-b2e2-4242f63715c2 Italy |
| Simplified SCIP | 8acdaa88-d2c8-4599-8b3b-bcaaba742e4b Norway |
| 49cd102c-3883-41cc-a96a-b8fcb24593e5 Belgium | |
| 657c96aa-3cfe-4bbc-b467-d9ddd211daae Germany | |
| 16909de5-bc32-4451-9cc1-efbf6e08ee50 Poland | |
| 6bc66a37-cca6-46cc-af8a-4b5b660bff79 Germany | |
| 0193a6e6-0495-4d86-9ff6-071c908856d3 Denmark | |
| 2d198c3a-2c83-4c73-823a-af634a71c37e Finland | |
| 50976a13-c14c-49a6-a5fd-01f91416ba25 Estonia | |
| cf5d357d-bb94-4dca-b82d-f961a61f4bed Sweden | |
| 021c71ff-9bed-4cc5-ac5c-218f19ec7fae Bulgaria | |
| beb537ab-80d5-4c26-aa27-ba9d94aca096 Greece | |
| 29ef254b-1bce-4415-82ee-71dc78e17228 Portugal | |
| 08ca7cff-e0ea-45f4-b9f3-f852bfe16d81 Poland | |
| e8fa3197-9d04-4d5e-991e-775c4101a809 Germany | |
| b04bcb7a-a3a8-4496-b103-5e862c6ae048 Croatia | |
| a1e1a5f4-4577-4fe1-8634-8162de036af1 Poland | |
| 73c4313d-5bb6-4068-abee-6d16ef44df55 Czech Republic | |
| ce88a11a-707e-4926-a5bc-9d72e6acd068 Hungary | |
| 96d5f54e-d500-434e-934b-aa722a4bc347 Netherlands | |
| 0af10433-4340-4656-acb5-176ce0555c43 France | |
| 8b5cbdaf-9560-42f9-ad21-c3713b24ca79 Sweden | |
| 8d20982b-ce31-456f-8ded-42a702caf85e France | |
| 5b27e2ab-cf52-4ff2-95a2-beb807211879 Spain | |
| 7a61fbf6-cd31-4b50-ba3a-c9cf88254c7a Germany | |
| 3b4b7e1d-d98e-49cf-bdf9-b468b6813419 Hungary | |
| f02f9a18-0375-4a47-b8e6-57331f825703 Germany | |
| 03a02cb2-c46e-4021-a9a9-95ffbc388334 Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BSEJBC000A000000XX |
| EAN | 8015644747138 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 14 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644747138 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Connecting Capacity | 1200 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 3000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 201 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |