View larger
1SDA071491R1
071491
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 24b5ed54-9181-4991-8fa5-fff30270d6f4 Italy |
| Simplified SCIP | ccf80e3a-991c-4c1e-9c7d-249bb343809d Germany |
| fc7763f1-59cf-41c5-9cd0-81773dc7830e Germany | |
| f0bce417-f16f-4f56-a53b-25f6f7a014bf Denmark | |
| f49cdebd-7b3f-45bc-9b48-bede10e08b2f Bulgaria | |
| f115e15f-d31b-4503-a1ab-f4f670570757 Belgium | |
| 84262c8e-3443-4a6e-93ef-143b098f264d Germany | |
| 2269ddc4-3fd9-4501-827c-7f1706092cb2 Sweden | |
| 95ba22ef-86de-4ce0-8877-600c241c7e26 Greece | |
| 3ff76fd2-b2b4-4a73-9e0e-f50c45d4aff6 Estonia | |
| cec6b913-201e-4977-b064-5a4d336373f2 France | |
| 59e0e7ac-f6ac-48e0-9834-04a85df1603a Germany | |
| d81dd6a8-482c-40b1-b8f6-fa3632e5cf7c Croatia | |
| f2d7768e-ec3a-4821-ab66-b546da0851cb Germany | |
| f22c8903-7fe7-4c99-98ca-4a5a8c9ea2e3 Hungary | |
| 43b23e6d-ce14-4944-a261-8da0b1e0a135 Norway | |
| 6252c2bd-b7e8-4c6d-ba87-0a5e58ef5408 Poland | |
| 759b0a9c-b52e-445d-8ef8-2c4cad87e54e Netherlands | |
| f4156e68-dcdd-4f6a-b099-f306a846ef0e France | |
| a48977fb-a60b-4066-a610-695f1945998a Finland | |
| 1c86c5b9-a42a-4df6-a006-cfd53173dcbf Portugal | |
| 4a955141-7aec-484c-81e2-b5bb55585cc7 Sweden | |
| 40d0b63d-eecb-40d7-8d30-def8343412c6 Poland | |
| 6b1080ea-f91d-4154-be0e-7c74a4933267 Poland | |
| afd5e4c4-e630-4c4d-8ca1-6d5074db6663 Czech Republic | |
| b64d6801-0856-4e66-bdbb-0d6ae4474e2e Hungary | |
| f67c19d8-19a8-4a57-af16-19aa232b3517 Belgium | |
| 769923c8-957f-4a2d-a076-57d11ffde6e3 Spain | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZABSEJBA000A000000XX |
| EAN | 8015644753412 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644753412 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 1200 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 3000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 201 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |