View larger
1SDA072806R1 ABB E1.2B 1250 Ekip Touch LSIG 4p WMP
1SDA072806R1
072806
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb 1SDA072806R1 circuit-breaker serves as an advanced protective device built to monitor electrical parameters and disconnect loads automatically during overloads or short circuits. Engineers incorporate these intelligent units into modern electrical switchboards to protect expensive machinery and ensure personnel safety.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: cfc43a1a-b389-4647-b734-3f2953f6a3e9 India
- Simplified SCIP: a336041f-5b9c-4143-927c-d4fc861c8565 Hungary
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZABREHAF000A000000XX
- EAN: 8015644766566
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | cfc43a1a-b389-4647-b734-3f2953f6a3e9 India |
| Simplified SCIP | a336041f-5b9c-4143-927c-d4fc861c8565 Hungary |
| 59f31506-d214-4183-9266-94d58d6c827b Hungary | |
| 23d904b1-839d-44f9-9e3e-963e9a1780cd Poland | |
| 1b8cfa4c-eb5e-4e74-b97f-14ba89015d1c Croatia | |
| 61a2f353-11a8-48e4-bf65-408c2ffb5d65 Czech Republic | |
| 6b3f03f1-f7a7-4377-8b3a-77f2a0a2cd5a Netherlands | |
| 04532a30-e437-4dee-aaee-bd8010ddbb4e Spain | |
| 0476d7b5-48e5-4801-9127-03fbbd713abc Belgium | |
| 47f35acc-7926-4fd8-b1c2-fbbdce71bd4e Estonia | |
| 7bd8e77b-341d-4193-97ba-626190be968e Germany | |
| 606a4e39-7818-4219-a8f0-2956cd6bf653 Sweden | |
| f2acb5de-536c-4a1a-86ac-b73a65381fa5 France | |
| f2e4f972-2b4a-40f8-bb2a-8a896a4dcbbc Portugal | |
| 7baeaa28-0604-4bd8-881e-573030ca3826 France | |
| a966530b-6188-4c37-9d5c-29f87cc84c75 Bulgaria | |
| 15c9d975-9502-4b0b-9023-3d487f31457a Germany | |
| 24f1dde6-0b99-42a9-9057-6ea5367695fe Poland | |
| 69cda600-7cc2-4a5f-9e92-05f9daae2024 Sweden | |
| 3fd257ad-9dbc-4638-9472-015514a9034d Greece | |
| 1d43e4c7-1efd-40cb-a527-4b088c174630 Poland | |
| dd90e1f4-1273-444a-b903-d3ed39ecabdc Norway | |
| 54048bd2-2c59-44c4-9acf-0ea2337223c5 Belgium | |
| d7eca887-f7b2-4393-8fd8-aada6e7f2ed1 Finland | |
| 08d11772-7fbb-408b-b380-4ace1ba0550d Germany | |
| 4bd1ff6d-064d-463b-8ef6-2dd8d5b07b4a Germany | |
| 0bc7492c-65e2-413d-b11b-6a9b33334ae7 Denmark | |
| 8c6992e8-b1cc-4425-b62c-95fe567a7a58 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZABREHAF000A000000XX |
| EAN | 8015644766566 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644766566 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0065 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 244 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |