View larger
1SDA072806R1
072806
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | cfc43a1a-b389-4647-b734-3f2953f6a3e9 India |
| Simplified SCIP | a336041f-5b9c-4143-927c-d4fc861c8565 Hungary |
| 59f31506-d214-4183-9266-94d58d6c827b Hungary | |
| 23d904b1-839d-44f9-9e3e-963e9a1780cd Poland | |
| 1b8cfa4c-eb5e-4e74-b97f-14ba89015d1c Croatia | |
| 61a2f353-11a8-48e4-bf65-408c2ffb5d65 Czech Republic | |
| 6b3f03f1-f7a7-4377-8b3a-77f2a0a2cd5a Netherlands | |
| 04532a30-e437-4dee-aaee-bd8010ddbb4e Spain | |
| 0476d7b5-48e5-4801-9127-03fbbd713abc Belgium | |
| 47f35acc-7926-4fd8-b1c2-fbbdce71bd4e Estonia | |
| 7bd8e77b-341d-4193-97ba-626190be968e Germany | |
| 606a4e39-7818-4219-a8f0-2956cd6bf653 Sweden | |
| f2acb5de-536c-4a1a-86ac-b73a65381fa5 France | |
| f2e4f972-2b4a-40f8-bb2a-8a896a4dcbbc Portugal | |
| 7baeaa28-0604-4bd8-881e-573030ca3826 France | |
| a966530b-6188-4c37-9d5c-29f87cc84c75 Bulgaria | |
| 15c9d975-9502-4b0b-9023-3d487f31457a Germany | |
| 24f1dde6-0b99-42a9-9057-6ea5367695fe Poland | |
| 69cda600-7cc2-4a5f-9e92-05f9daae2024 Sweden | |
| 3fd257ad-9dbc-4638-9472-015514a9034d Greece | |
| 1d43e4c7-1efd-40cb-a527-4b088c174630 Poland | |
| dd90e1f4-1273-444a-b903-d3ed39ecabdc Norway | |
| 54048bd2-2c59-44c4-9acf-0ea2337223c5 Belgium | |
| d7eca887-f7b2-4393-8fd8-aada6e7f2ed1 Finland | |
| 08d11772-7fbb-408b-b380-4ace1ba0550d Germany | |
| 4bd1ff6d-064d-463b-8ef6-2dd8d5b07b4a Germany | |
| 0bc7492c-65e2-413d-b11b-6a9b33334ae7 Denmark | |
| 8c6992e8-b1cc-4425-b62c-95fe567a7a58 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZABREHAF000A000000XX |
| EAN | 8015644766566 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644766566 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0065 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 244 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |