View larger
1SDA072172R1
072172
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | be955d7d-0a03-47ba-938f-552087ae2c6a Italy |
| Simplified SCIP | 96edba7c-8b12-4d61-8101-c42f6220842a Germany |
| e53297b1-7303-4e34-90e4-ddfa4cc163f7 Belgium | |
| a6c0e7e9-8759-4fa5-8d9b-4dd8484b8f1e Sweden | |
| 49cd54f7-3405-4708-8a28-88b6359757c2 Czech Republic | |
| 8ec5a395-5577-4ab2-abe7-7b0f2606e2ea Greece | |
| 3e787125-8135-4f90-a44e-796d8ce49ab0 Portugal | |
| 952a0f68-22c2-4895-a55b-93def13e01c5 Sweden | |
| 35c9c053-2f11-4c8b-b530-8d4ff3ac85fe Poland | |
| 4f3200f0-29cd-4f1a-b8e9-95de2bfb5ba8 Poland | |
| 496fcbb8-4d82-4bf8-8a05-365e8fc3607f Germany | |
| cf757bcf-30f7-4c62-933a-fe5ae614b7de Denmark | |
| e5df35e9-6c93-4792-b4ca-733bff8d2b75 Bulgaria | |
| 6b918e40-d872-41b8-b1f0-5f23fa7e4415 Estonia | |
| 34395226-a74c-455f-b1ed-4aa3230b9f30 Hungary | |
| 56bd8933-a12e-4ddf-b083-3fd0f73a0f3d Norway | |
| 130cc730-6527-4430-9171-d9763081d4b0 France | |
| f0291d22-8b27-460e-aef3-f18041fe938c Croatia | |
| b86b6908-402e-4a84-8be9-52a38ab91e58 Poland | |
| 35fcab29-3bb8-470d-ad92-85655be214d5 Germany | |
| c896dfaa-84f7-41c3-b2fd-c22f54a46a8a France | |
| 64234dd5-80dd-4c99-96f0-fbb4f7e893c7 Germany | |
| 96961053-36a3-42dc-8f70-ba267333857a Germany | |
| 52af8b71-e2c4-4569-b4a6-f59bc0f184a2 Hungary | |
| 16a1c5fd-1987-486c-b7c6-18d32940532b Netherlands | |
| 9ef93334-f375-4a69-850d-03015cb343e9 Spain | |
| 4b8b3d1a-a2ff-4056-9979-3a5dd1452b30 Belgium | |
| 9e26d903-77ff-42bd-b2ba-6afda7c643fc Finland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BREHAB000A000000XX |
| EAN | 8015644760229 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644760229 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 244 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |