1SDA072172R1 ABB E1.2B 1250 Ekip Dip LSI 3p WMP
1SDA072172R1
072172
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
ABB E1.2B 1250 Ekip Dip LSI 3p WMP (part number 1SDA072172R1) is an air circuit breaker designed for high-capacity electrical distribution systems. It provides advanced overcurrent protection and isolation for main switchboards in heavy industrial environments.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: be955d7d-0a03-47ba-938f-552087ae2c6a Italy
- Simplified SCIP: 96edba7c-8b12-4d61-8101-c42f6220842a Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1BREHAB000A000000XX
- EAN: 8015644760229
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | be955d7d-0a03-47ba-938f-552087ae2c6a Italy |
| Simplified SCIP | 96edba7c-8b12-4d61-8101-c42f6220842a Germany |
| e53297b1-7303-4e34-90e4-ddfa4cc163f7 Belgium | |
| a6c0e7e9-8759-4fa5-8d9b-4dd8484b8f1e Sweden | |
| 49cd54f7-3405-4708-8a28-88b6359757c2 Czech Republic | |
| 8ec5a395-5577-4ab2-abe7-7b0f2606e2ea Greece | |
| 3e787125-8135-4f90-a44e-796d8ce49ab0 Portugal | |
| 952a0f68-22c2-4895-a55b-93def13e01c5 Sweden | |
| 35c9c053-2f11-4c8b-b530-8d4ff3ac85fe Poland | |
| 4f3200f0-29cd-4f1a-b8e9-95de2bfb5ba8 Poland | |
| 496fcbb8-4d82-4bf8-8a05-365e8fc3607f Germany | |
| cf757bcf-30f7-4c62-933a-fe5ae614b7de Denmark | |
| e5df35e9-6c93-4792-b4ca-733bff8d2b75 Bulgaria | |
| 6b918e40-d872-41b8-b1f0-5f23fa7e4415 Estonia | |
| 34395226-a74c-455f-b1ed-4aa3230b9f30 Hungary | |
| 56bd8933-a12e-4ddf-b083-3fd0f73a0f3d Norway | |
| 130cc730-6527-4430-9171-d9763081d4b0 France | |
| f0291d22-8b27-460e-aef3-f18041fe938c Croatia | |
| b86b6908-402e-4a84-8be9-52a38ab91e58 Poland | |
| 35fcab29-3bb8-470d-ad92-85655be214d5 Germany | |
| c896dfaa-84f7-41c3-b2fd-c22f54a46a8a France | |
| 64234dd5-80dd-4c99-96f0-fbb4f7e893c7 Germany | |
| 96961053-36a3-42dc-8f70-ba267333857a Germany | |
| 52af8b71-e2c4-4569-b4a6-f59bc0f184a2 Hungary | |
| 16a1c5fd-1987-486c-b7c6-18d32940532b Netherlands | |
| 9ef93334-f375-4a69-850d-03015cb343e9 Spain | |
| 4b8b3d1a-a2ff-4056-9979-3a5dd1452b30 Belgium | |
| 9e26d903-77ff-42bd-b2ba-6afda7c643fc Finland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BREHAB000A000000XX |
| EAN | 8015644760229 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644760229 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 244 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |