1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
ABB 1SDA070785R1 is an advanced molded case or air circuit-breaker component designed to monitor and interrupt high current loads within industrial power grids. This protective element prevents catastrophic electrical failures by rapidly isolating overcurrents and short circuits in complex installations.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 98af3829-6bf4-4247-8692-511d22267351 Italy
- Simplified SCIP: 969a53fd-641b-4b62-8879-86305fb02811 Hungary
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1BQEGBE000A000000XX
- EAN: 8015644746353
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 98af3829-6bf4-4247-8692-511d22267351 Italy |
| Simplified SCIP | 969a53fd-641b-4b62-8879-86305fb02811 Hungary |
| 5e6a392a-3377-43bd-80e6-7e33749b3fe1 Sweden | |
| 49f1bc1b-4170-40dc-a626-9f36703d6cf8 France | |
| 3afa4c95-8ee0-4a5e-811f-8cab2d075008 Poland | |
| 195c9bfb-2f8c-422a-b590-0ceb6eb43098 Germany | |
| 5e6a392a-3377-43bd-80e6-7e33749b3fe1 Sweden | |
| 4f7260aa-7f3c-4f8e-a2c8-359d428586f0 Spain | |
| 4825f0cd-4b99-43c0-839b-a323471fc3cb Greece | |
| 6041c228-b054-4f36-aa7d-b442e0c8df16 Netherlands | |
| 38674921-6472-4921-bb2b-2b69650923a9 Hungary | |
| c654d30e-12fe-4ef9-85b4-d7ee14f0f0db Sweden | |
| e38d3cb9-34a3-4d79-bac5-063ece1bb251 France | |
| 4825f0cd-4b99-43c0-839b-a323471fc3cb Greece | |
| 49d71a07-f02a-4bd0-8029-e7e54fffe824 Estonia | |
| af22bdad-0d29-4be4-b3f8-8eb970de391f Bulgaria | |
| 86f929c2-e785-4e30-a8c6-e30f636edbc8 Poland | |
| 6041c228-b054-4f36-aa7d-b442e0c8df16 Netherlands | |
| 97af705b-003f-42a6-9c04-1dd3acf4dbc5 Poland | |
| 8c196a9d-3557-4599-9bc7-233f7c5e59dc Portugal | |
| 65ef0954-9a70-4656-8671-52982ac52a91 Croatia | |
| ae8206aa-3ae4-42e6-8573-3e39ccf92462 Germany | |
| a76ac0c9-8d73-45bc-be7a-81ab78fcabce Denmark | |
| 0f8e8069-5a4f-4ee6-8696-49e080e6c289 Germany | |
| ae8206aa-3ae4-42e6-8573-3e39ccf92462 Germany | |
| d99078b7-5573-40e9-87fb-a7a3418b349f Norway | |
| 5a33431f-58a4-400d-b953-ea60daf374ee Belgium | |
| 86f929c2-e785-4e30-a8c6-e30f636edbc8 Poland | |
| 65ef0954-9a70-4656-8671-52982ac52a91 Croatia | |
| 086b61b8-dedd-4b40-a6a9-e16ddc65e5dc Germany | |
| 8159cfbd-752b-4193-9784-d40eddd051cf Germany | |
| 3afa4c95-8ee0-4a5e-811f-8cab2d075008 Poland | |
| 156d45a0-ee27-4bb3-9ca5-d02123dacb85 Belgium | |
| 8159cfbd-752b-4193-9784-d40eddd051cf Germany | |
| a76ac0c9-8d73-45bc-be7a-81ab78fcabce Denmark | |
| c3f13b18-6749-4abd-8b0f-ba2b36aafadc Finland | |
| 97af705b-003f-42a6-9c04-1dd3acf4dbc5 Poland | |
| c654d30e-12fe-4ef9-85b4-d7ee14f0f0db Sweden | |
| 0f8e8069-5a4f-4ee6-8696-49e080e6c289 Germany | |
| 156d45a0-ee27-4bb3-9ca5-d02123dacb85 Belgium | |
| 38674921-6472-4921-bb2b-2b69650923a9 Hungary | |
| e38d3cb9-34a3-4d79-bac5-063ece1bb251 France | |
| 4f7260aa-7f3c-4f8e-a2c8-359d428586f0 Spain | |
| b2afccfd-e441-4dff-80eb-32a95c776839 Czech Republic | |
| af22bdad-0d29-4be4-b3f8-8eb970de391f Bulgaria | |
| 086b61b8-dedd-4b40-a6a9-e16ddc65e5dc Germany | |
| b2afccfd-e441-4dff-80eb-32a95c776839 Czech Republic | |
| d99078b7-5573-40e9-87fb-a7a3418b349f Norway | |
| 49f1bc1b-4170-40dc-a626-9f36703d6cf8 France | |
| 5a33431f-58a4-400d-b953-ea60daf374ee Belgium | |
| c3f13b18-6749-4abd-8b0f-ba2b36aafadc Finland | |
| 969a53fd-641b-4b62-8879-86305fb02811 Hungary | |
| 8c196a9d-3557-4599-9bc7-233f7c5e59dc Portugal | |
| 195c9bfb-2f8c-422a-b590-0ceb6eb43098 Germany | |
| 49d71a07-f02a-4bd0-8029-e7e54fffe824 Estonia | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BQEGBE000A000000XX |
| EAN | 8015644746353 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 14 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644746353 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 78 W |
| Rated Current (In) | 1000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M10 |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |