View larger
Images are for illustrative purposes only. Please refer to data sheet for details
1SDA072132R1 ABB E1.2B 1000 Ekip Dip LSI 3p WMP
1SDA072132R1
072132
ABB
1 Pcs.
E1.2B 1000 Ekip Dip LSI 3p WMP
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB E1.2B 1000 Ekip Dip LSI 3p WMP air circuit breaker offers dependable overload and short-circuit protection for heavy-duty commercial and industrial electrical installations.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2360
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1425
- RoHS Information: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: a62df1c2-d3f0-4b8b-be72-5ee5ab5a5717 Italy (IT)
- Simplified SCIP: fb12e75b-347a-4a7d-8ba7-27a8b6e6e636 Germany (DE)
- Order Code US and Canada: Z1BQEGAB000A000000XX
- EAN: 8015644759827
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2360 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | a62df1c2-d3f0-4b8b-be72-5ee5ab5a5717 Italy (IT) |
| Simplified SCIP | fb12e75b-347a-4a7d-8ba7-27a8b6e6e636 Germany (DE) |
| d23e68a3-c6d5-411d-ba99-b34bc5594823 Bulgaria (BG) | |
| 31565003-f404-43ed-9f86-9975594a846d Portugal (PT) | |
| ce744ae3-3b13-4c5b-bc85-9e218077f230 Poland (PL) | |
| baf3a315-d833-4a55-ac2c-f96ad5e98ec3 Sweden (SE) | |
| 4a88f3e0-d5b1-4b10-9ec4-735e28a8dc48 Hungary (HU) | |
| fc76644c-b6da-48bf-beba-530f1e12551a Sweden (SE) | |
| ae39e0d4-449e-4cd7-9ca3-b2fc7f318ea7 Belgium (BE) | |
| 6f1483f1-314c-4d42-8df8-6072827422c9 Croatia (HR) | |
| d6ff0687-7e54-4370-8eb7-05538e7b0142 Finland (FI) | |
| 19cf89af-1d13-4b2b-9937-9979d7d7c59f France (FR) | |
| 7012e627-4bd4-423b-88b7-2e84f9d59ef2 Germany (DE) | |
| da67eb6a-6d2f-4693-8448-ef0c852560c3 Denmark (DK) | |
| b45d2d87-ffed-491c-9a90-165a86004142 Norway (NO) | |
| 77c6200a-760b-43d7-9bec-d5e116e04357 Poland (PL) | |
| d5ad702a-f321-432b-a91b-7d335581db66 Czech Republic (CZ) | |
| a0782129-5f5a-4ded-aead-a4ca6120e741 Germany (DE) | |
| a760b844-35f5-498c-b0ca-e1d401cfaa8e Germany (DE) | |
| 653ea291-7e83-4bf8-ae8b-731df659ce96 Germany (DE) | |
| 4535464f-48af-4df8-ad31-9b62192eda60 Poland (PL) | |
| ca628a74-d9d0-4fc7-906e-3b44920dc50c Hungary (HU) | |
| 8b8f6bd8-8b3f-472d-9b9d-7929fe9cc397 France (FR) | |
| 56e0ccf8-bb85-4ef6-9005-00f47ae950bc Spain (ES) | |
| 7b5e0f27-fb9d-4178-9cac-1f6d017cfbd7 Belgium (BE) | |
| 142c3d8d-8335-4a7f-ad6e-3be15b9625c3 Netherlands (NL) | |
| 36d4df87-5b07-4971-88a2-3f4972bf3a12 Greece (GR) | |
| 384eb336-c866-4eef-a090-0b1db1f5743d Estonia (EE) | |
| Ordering | |
| Order Code US and Canada | Z1BQEGAB000A000000XX |
| EAN | 8015644759827 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644759827 |
| Additional Information | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3 |
| Power Loss | 156 W |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Current (In) | 1000 A |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |