View larger
1SDA072761R1 ABB E1.2B 1000 Ekip Dip LI 4p WMP
1SDA072761R1
072761
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The 1SDA072761R1 ABB E1.2B 1000 Ekip Dip LI 4p WMP is an air circuit breaker engineered for reliable fault protection and load switching in heavy-duty power distribution infrastructures. Circuit breakers of this class safeguard electrical grids and connected equipment by automatically interrupting dangerous overloads or short-circuit currents.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: a9b853e2-734a-42bb-b651-01d65c5685c3 China
- Simplified SCIP: b8dc20eb-f4d4-49ca-a8d4-b1c062204e4f Finland
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZABQEGAA000A000000XX
- EAN: 8015644766115
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | a9b853e2-734a-42bb-b651-01d65c5685c3 China |
| Simplified SCIP | b8dc20eb-f4d4-49ca-a8d4-b1c062204e4f Finland |
| d4dbad94-7ea1-4d45-b450-df2cec612120 Portugal | |
| 7377c4b7-f6e1-43f2-8561-94ea8c0d2ac6 Czech Republic | |
| 7a69cbc6-0316-4d87-8a1c-3a4528dba2ba Spain | |
| 7b0937d1-65cf-4a74-b03e-2f7084ffe0b4 Hungary | |
| ad9e1f71-2c36-45fc-92e9-ad635ad1fe09 Belgium | |
| dc600c97-3202-4fa5-92fd-5e52777bcb0c Germany | |
| 27226044-f518-4cf4-8e07-1055badc1be8 Norway | |
| f8a8d75b-2038-4a8c-b418-4a23943d68bf Croatia | |
| 2cabb13f-d677-47a8-a502-081573708905 Hungary | |
| 723d8805-702f-4c39-b73a-24b4c448db59 Estonia | |
| 07c33e0d-480e-4db6-b736-d809bf5364ba Poland | |
| 4bca4ca9-ea0c-477d-b1c5-c36594d42189 Greece | |
| f50be7f6-8ada-4529-8606-b59a4857ae61 Bulgaria | |
| 7c5e6c31-2a7e-4e1c-9cab-317a802e08f2 Poland | |
| cef3f608-141c-448f-aa4f-e5abae4e04eb Sweden | |
| b764cbbd-2b0a-4c2d-80e2-5a5776623a82 France | |
| 3bef4198-6059-4acf-b2e0-c4ee5797bb20 Belgium | |
| 1a83b7b4-e55b-431f-9088-80d906b46626 France | |
| 3a3ec58c-852e-4ae6-acb4-7782b19f9a01 Denmark | |
| b81708ce-3375-4100-8320-8cb74fc5d84e Germany | |
| 6b7217e2-f50d-472b-b57b-51e30ffd95fe Sweden | |
| 061e57a3-7705-429e-8ed5-dd6a3b5659d6 Germany | |
| 66639f4f-57ce-4d7a-a844-1674e11e8c5d Germany | |
| 7a204565-1663-4ce2-b348-df8dc786db0e Germany | |
| 64002fcd-b82b-4f3c-a60c-8dcc849f8234 Netherlands | |
| 1aeab005-e680-41ab-b05b-eec1d218dd19 Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZABQEGAA000A000000XX |
| EAN | 8015644766115 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644766115 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0065 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 156 W |
| Rated Current (In) | 1000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |