View larger
1SVR730040R3300 ABB CT-WBS.22S Time relay, impulse & flasher 2c/o, 24-48VDC, 24-240VAC
1SVR730040R3300
730040
ABB
1 Pcs.
Automation > Timer relay
CTS Time
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb time relay provides impulse and flasher control capabilities within industrial automation systems, managing cyclical switching operations and periodic signal generation. Flasher relays are commonly deployed in warning indicators, process control loops, and sequential machine startups.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- EAN: 4016779851435
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 2CDC110004C0210_01
- Instructions and Manuals: 1SVC730050M1000
- CAD Dimensional Drawing: 2CDC001079B0201
- EPLAN Data: 9AAC201310_EPLAN
- Product Net Width: 22.5 mm
- Product Net Height: 85.6 mm
- Product Net Depth / Length: 103.7 mm
- Product Net Weight: 0.123 kg
- Timer Relay Type: Flasher Starting with OFF; Time Range: 0.05 s ... 300 h
- Rated Control Supply Voltage (U s ): 24 ... 240 V AC
- Rated Operational Voltage: Auxiliary Circuit 250 V
- Rated Frequency (f): 50 / 60 Hz
More info
▲| Ordering | |
|---|---|
| EAN | 4016779851435 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC110004C0210_01 |
| Instructions and Manuals | 1SVC730050M1000 |
| 1SVC730050M0000 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC201310_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.123 kg |
| Technical | |
| Timer Relay Type | Flasher Starting with OFF |
| Flasher Starting with ON | |
| Impulse ON | |
| ON-Delay | |
| Adjustable Impulse with Fixed Time Delay | |
| Fixed Impulse with Adjustable Time Delay | |
| ON / OFF Function | |
| Time Range | 0.05 s ... 300 h |
| Rated Control Supply Voltage (Us) | 24 ... 240 V AC |
| 24 ... 48 V DC | |
| Rated Operational Voltage | Auxiliary Circuit 250 V |
| Rated Frequency (f) | 50 / 60 Hz |
| DC | |
| Output | 2 C/O Contacts |
| Terminal Type | Screw Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 12 V |
| 100 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Input Circuit 4 kV |
| Output Circuit 1 / Output Circuit 2 4 kV | |
| Rated Insulation Voltage (Ui) | Input Circuit / Output Circuit 500 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible with Ferrule 1x 0.5 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible 1x 0.5 ... 2.5 mm² | |
| Flexible 2x 0.5 ... 1.5 mm² | |
| Rigid 1x 0.5 ... 4 mm² | |
| Rigid 2x 0.5 ... 2.5 mm² | |
| Tightening Torque | 0.6 ... 0.8 N·m |
| Wire Stripping Length | 8 mm |
| Recommended Screw Driver | 0.8 x 4 |
| 4.5 | |
| Pozidriv 1 | |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| IEC/EN 63000 | |
| IEC/EN 61812-1 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 1x 18-14 AWG |
| Flexible 2x 18-16 AWG | |
| Rigid 1x 20-12 AWG | |
| Rigid 2x 20-14 AWG | |
| Tightening Torque UL/CSA | 7.08 in·lb |
| Pilot Duty UL/CSA | B300 |
| Flammability According to UL94 | V-0 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | e129f004-824b-4f32-bbf2-35a85e0d516b Germany |
| Simplified SCIP | 9f790993-6683-4a2c-a702-53400e6a1c81 France |
| 1c331a21-08c0-45e2-a42a-2d47a035754b Germany | |
| efd3e620-e2fb-46df-a99d-f4b4e86f9a6b Poland | |
| e3c35fb9-c642-4b7b-9659-6f7a93bf8c3a Hungary | |
| 1ce22d22-1a5a-4217-9a2e-0018a364512a Bulgaria | |
| fd766528-46bb-4fc2-9e0d-168701e71403 Germany | |
| 930aab95-2101-48b2-8dc5-a2ba7147e0ff Germany | |
| 61f45262-fe41-4717-a13e-40f91eba67d0 Denmark | |
| ac1e5ae9-7e0f-4eed-b63c-e35801738d84 Belgium | |
| c954df41-c97f-40a6-b553-8b1fe8f432c3 Italy | |
| e7e58e89-70d3-4c30-8926-99e923a9ba82 Finland | |
| b781dc47-96cc-4664-9a69-5b4fc7bfe227 Germany | |
| d18573bd-dec3-4af8-ac2e-f0499901c850 Czech Republic | |
| 4cb1a826-e45b-4b1f-9974-ccf07389958d Poland | |
| ad8b92fa-21b8-4b20-9e03-cf4f4d4937c0 Netherlands | |
| 41700964-7966-43f4-9d03-a2db878e0221 Estonia | |
| 7310b25f-fdbe-48bf-b827-2800edd6064b Poland | |
| 81e5afd4-3a84-4bfc-b090-558b7f5659c1 Greece | |
| eedd1077-52f6-4dfe-ae2e-754fc217b2bb Hungary | |
| f9b4a91e-b51f-4f21-b5b0-937baceb81b1 Belgium | |
| cb539878-f3ac-40a4-b511-5f446e23cb21 Spain | |
| e4cf178d-bda1-4596-bce8-24dd8ceee916 Portugal | |
| b24a7640-fbd5-408f-b253-3ef6eebc4d1a Sweden | |
| 6e27fa4b-6cc2-466f-9c34-073c5e6dd662 France | |
| 9df9ae0a-a1cd-4b42-9d76-71ab6163701c Norway | |
| c6d7ffc8-2127-4d98-b26b-520b92c08760 Croatia | |
| c84afbbd-886f-4bc6-a137-6a3e222983e6 Sweden | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| Environmental Product Declaration - EPD | 1SAC200371M0001 |
| Certificates and Declarations | |
| CQC Certificate | CQC2007010303255979 |
| cULus Certificate | cULus508_20110711-E140448A |
| Declaration of Conformity - CCC | 2020980303000207 |
| Declaration of Conformity - CE | 1SVD981008 |
| Declaration of Conformity - UKCA | 1SVD981008-10 |
| DNV GL Certificate | DNV_GL_TAA00000XR |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.145 kg |
| Package Level 1 EAN | 4016779851435 |
| External Classifications and Standards | |
| Object Classification Code | K |
| ETIM 7 | EC001439 - Timer relay |
| ETIM 8 | EC001439 - Timer relay |
| ETIM 9 | EC001439 - Timer relay |
| eClass | V11.0 : 27371605 |
| UNSPSC | 39122329 |
| E-Number (Finland) | 2712201 |
| E-Number (Norway) | 4187942 |
| E-Number (Sweden) | 4033113 |