View larger
1SVR730211R2300 ABB CT-SDS.23S Time relay, star-delta 2n/o, 380-440VAC
1SVR730211R2300
730211
ABB
1 Pcs.
Automation > Timer relay
CTS Time
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Abb 1SVR730211R2300 is a specialized star-delta time relay configured to manage the startup phase of heavy-duty induction motors. Star-delta timers reduce initial inrush current by switching motor windings from star to delta configuration once the rotor reaches operational speed. Confirm pricing, availability and lead time per enquiry through an RFQ.
- EAN: 4016779851541
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 2CDC110004C0210_01
- Instructions and Manuals: 1SVC730050M1000
- CAD Dimensional Drawing: 2CDC001079B0201
- EPLAN Data: 9AAC201310_EPLAN
- Product Net Width: 22.5 mm
- Product Net Height: 85.6 mm
- Product Net Depth / Length: 103.7 mm
- Product Net Weight: 0.118 kg
- Timer Relay Type: Star-Delta
- Time Range: 0.05 s ... 10 minute [unit of time]
- Rated Control Supply Voltage (U s ): 380 ... 440 V AC
- Rated Operational Voltage: Auxiliary Circuit 250 V
- Rated Frequency (f): 50 / 60 Hz
More info
▲| Ordering | |
|---|---|
| EAN | 4016779851541 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC110004C0210_01 |
| Instructions and Manuals | 1SVC730050M1000 |
| 1SVC730050M0000 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC201310_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.118 kg |
| Technical | |
| Timer Relay Type | Star-Delta |
| Time Range | 0.05 s ... 10 minute [unit of time] |
| Rated Control Supply Voltage (Us) | 380 ... 440 V AC |
| Rated Operational Voltage | Auxiliary Circuit 250 V |
| Rated Frequency (f) | 50 / 60 Hz |
| Output | 2 N/O Contacts |
| Terminal Type | Screw Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 12 V |
| 100 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Input Circuit 4 kV |
| Output Circuit 1 / Output Circuit 2 4 kV | |
| Rated Insulation Voltage (Ui) | Input Circuit / Output Circuit 500 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible with Ferrule 1x 0.5 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible 1x 0.5 ... 2.5 mm² | |
| Flexible 2x 0.5 ... 1.5 mm² | |
| Rigid 1x 0.5 ... 4 mm² | |
| Rigid 2x 0.5 ... 2.5 mm² | |
| Tightening Torque | 0.6 ... 0.8 N·m |
| Wire Stripping Length | 8 mm |
| Recommended Screw Driver | 0.8 x 4 |
| 4.5 | |
| Pozidriv 1 | |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| IEC/EN 63000 | |
| IEC/EN 61812-1 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 1x 18-14 AWG |
| Flexible 2x 18-16 AWG | |
| Rigid 1x 20-12 AWG | |
| Rigid 2x 20-14 AWG | |
| Tightening Torque UL/CSA | 7.08 in·lb |
| Pilot Duty UL/CSA | B300 |
| Flammability According to UL94 | V-0 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | 90aff9de-6b6e-4746-b3f9-b3f192e128b0 Germany |
| Simplified SCIP | 8ca92acd-9bd7-4c8d-bb34-27832236c20d Italy |
| f65dbeb3-7549-42c1-ad2f-70e1c42915ea Germany | |
| f7b92c8e-c83a-454d-9495-ba8acd66e10d Hungary | |
| b82f2d68-74c7-4815-8810-18b6d40d6fb6 Germany | |
| 63a7da29-5754-4aae-b5b7-ea3c7b5f07d6 Czech Republic | |
| 9e180bfa-9410-452e-b35f-258b1ffe9745 Croatia | |
| 0fb85971-043a-48a0-86c1-aea07abaeb5c Denmark | |
| 494a5736-c9f0-4b48-af92-0bccc19194d3 Germany | |
| 75e0b353-62eb-41aa-a0a2-24c9f031fbf4 Poland | |
| 33d92ec5-e444-4b4a-8a9d-e656fd454a89 Germany | |
| 37c59cbc-d90f-4368-beb4-ed46ea3f02e8 Belgium | |
| 7bdaa580-0f47-44c7-8cc8-d17660bfb6c2 Finland | |
| 4573bd1a-6ab8-445c-9df2-9539d7e57ecd Norway | |
| 3418fa2e-1c9f-4174-940e-5832b2bbadc3 Bulgaria | |
| 0a658507-10e2-4a74-a5ba-53bbedcfd9e6 Greece | |
| 124a1c7f-81ec-4183-85a6-9da2d5066cff Portugal | |
| 89bd56bf-a39b-4532-be8d-da7adfb3ad62 Estonia | |
| fc06e845-2dc5-4936-9589-8af835711eeb Hungary | |
| 9b38cff0-3d5a-448b-826a-289105b9f5c8 Netherlands | |
| 6dd9b44c-cbb5-41d2-81e3-71ad2b1d0d93 Poland | |
| 63a2865c-a59e-4193-8dba-dc080f59d53f Poland | |
| c881c8b9-d04b-43fc-a4eb-60bd90de6c9d Sweden | |
| d15bda22-0d2d-4ce9-b74e-0c582dcf1d40 Belgium | |
| 5b7ff623-3884-41e6-98b2-5703264bd3c7 Spain | |
| efc1136f-e944-4b65-b12f-bd296892979b France | |
| 6d10795b-a41e-4059-8419-9388f377f8ff France | |
| 18168391-15e4-4a48-b8c7-a159f917d146 Sweden | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| Environmental Product Declaration - EPD | 1SAC200371M0001 |
| Certificates and Declarations | |
| CQC Certificate | CQC2007010303255979 |
| cULus Certificate | cULus508_20110711-E140448A |
| Declaration of Conformity - CCC | 2020980303000207 |
| Declaration of Conformity - CE | 1SVD981008 |
| Declaration of Conformity - UKCA | 1SVD981008-10 |
| DNV GL Certificate | DNV_GL_TAA00000XR |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.14 kg |
| Package Level 1 EAN | 4016779851541 |
| External Classifications and Standards | |
| Object Classification Code | K |
| ETIM 7 | EC001439 - Timer relay |
| ETIM 8 | EC001439 - Timer relay |
| ETIM 9 | EC001439 - Timer relay |
| eClass | V11.0 : 27371605 |
| UNSPSC | 39122329 |
| E-Number (Finland) | 2712212 |
| E-Number (Norway) | 4187966 |
| E-Number (Sweden) | 4033124 |