ABB 1SVR740100R3300 1SVR740100R3300 ABB CT-ERS.22P Time relay, ON-delay 2c/o, 24-48VDC, 24-240VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR740100R3300 ABB CT-ERS.22P Time relay, ON-delay 2c/o, 24-48VDC, 24-240VAC

1SVR740100R3300

740100

ABB

1 Pcs.

CT-ERS.22P Time relay, ON-delay 2c/o, 24-48VDC, 24-240VAC CT-ERS.22P TEMPO RET. CONEX. 2 C/C RESORT

Automation > Timer relay
CTS Time

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4016779851671
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC110004C0210_01
Instructions and Manuals1SVC730050M1000
1SVC730050M0000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC201310_EPLAN
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.113 kg
Technical
Timer Relay TypeON-Delay
Time Range0.05 s ... 300 h
Rated Control Supply Voltage (Us)24 ... 240 V AC
24 ... 48 V DC
Rated Operational VoltageAuxiliary Circuit 250 V
Rated Frequency (f)50 / 60 Hz
DC
Output2 C/O Contacts
Terminal TypeScrewless Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity12 V
100 mA
Rated Impulse Withstand Voltage (Uimp)Input Circuit 4 kV
Output Circuit 1 / Output Circuit 2 4 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 500 V
Output Circuit 1 / Output Circuit 2 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 2x 0.5 ... 1.5 mm²
Wire Stripping Length8 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 61812-1
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 2x 18-16 AWG
Rigid 2x 20-16 AWG
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIP2dfd3963-5609-4726-81c4-4f2a48349fc2 Germany
Simplified SCIP92accf1f-2e93-4c12-bc49-7ee69d6da960 Bulgaria
68a81138-3836-4aa0-b907-f4f578be7323 France
e7992010-8e1a-4c95-8b60-cf74ee69113f Germany
d9255359-a41a-4892-aa2a-1531828b3ed2 Portugal
4a65f0f7-a7ee-465d-89de-8cdf1d00fe5b Hungary
0beab511-1f45-4443-8bba-5333c87f5173 France
b238b62f-c9d3-4381-babe-8e926f0c99f4 Hungary
a1e7d61d-6165-4c50-90f6-5827a3f3a00e Spain
e0d00e4d-b1ea-4b3f-a353-b996701a88bd Belgium
a7072138-47a4-47d2-ab59-9400ce9fa938 Belgium
72a63ab7-8c60-4653-8039-71475572a6b0 Germany
d933c1a7-c326-4400-bccb-5890b82892ab Poland
b16ca192-6330-41f3-9d86-4ca103380952 Finland
fa1dac46-6461-490a-9b55-d50ffb2c0ad8 Poland
9628410d-5777-485e-88c3-8e8d99c340be Czech Republic
44750e70-7252-496b-9a01-afa08622f030 Denmark
03706010-c930-483c-86fe-593abd40bfc9 Germany
b6fc20d5-eae0-4d54-9707-85ebf6908c42 Sweden
78c89cba-fd6a-419f-91ad-68a65859954a Poland
c26c9165-4802-4390-a736-1962901cbc53 Estonia
0fa91a64-a223-4763-82be-07936af91b05 Netherlands
2c95e7e7-5a96-4389-9607-aa004d11b3ba Italy
7e683a3f-e618-4188-9907-32a6459d15ac Germany
28471d2b-17b6-403f-9e98-a58a2af3695d Croatia
75ab8112-dbd1-4348-902b-cdfe7f44f506 Sweden
2f6afb57-b7e9-4aab-8517-48879d1a2629 Greece
a8dd9155-4a38-4dca-a57f-4f190f2e4995 Norway
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
ABB EcoSolutionsYes
Environmental Product Declaration - EPD1SAC200371M0001
Certificates and Declarations
CQC CertificateCQC2007010303255979
cULus CertificatecULus508_20110711-E140448A
Declaration of Conformity - CCC2020980303000207
Declaration of Conformity - CE1SVD981008
Declaration of Conformity - UKCA1SVD981008-10
DNV GL CertificateDNV_GL_TAA00000XR
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.135 kg
Package Level 1 EAN4016779851671
External Classifications and Standards
Object Classification CodeK
ETIM 7EC001439 - Timer relay
ETIM 8EC001439 - Timer relay
ETIM 9EC001439 - Timer relay
eClassV11.0 : 27371605
UNSPSC39122329
E-Number (Finland)2712223
E-Number (Norway)4187949
E-Number (Sweden)4033135

ETIM for 1SVR740100R3300 Relays (EC001439)
Feature Name Feature Value
Type of electric connection (EF003961) Spring clamp connection
Function delay-on energization (EF003374) Yes
Function delay on de-energization (EF003401) No
Function floating contact on energization (EF003378) No
Function floating contact on de-energization (EF003402) No
Function star-delta (EF003380) No
Function pulse shaping (EF003403) No
Function flashing, starting with pause, fixed time (EF003363) No
Function flashing, starting with pulse, fixed time (EF003364) No
Clock function, starting with pause, variable (EF003365) No
Clock function, starting with pulse, variable (EF003366) No
Remote operation possible (EF003361) No
Suitable as remote control (EF003362) No
Pluggable on auxiliary contact block (EF006952) No
Rated control supply voltage AC 50 Hz (EF003978) 24 V
Rated control supply voltage AC 60 Hz (EF003979) 24 V
Rated control supply voltage DC (EF003980) 24 V
Voltage type for actuating (EF008242) AC/DC
Nominal current (EF000001) 4 A
Time range (EF003384) 0.05 s
Number of outputs, undelayed, normally closed contact (EF006835) 0
Number of outputs, undelayed, normally open contact (EF006836) 0
Number of outputs, undelayed, change-over contact (EF006837) 2
Number of outputs, delayed, normally closed contact (EF006838) 0
Number of outputs, delayed, normally open contact (EF006839) 0
Number of outputs, delayed, change-over contact (EF006840) 2
Outputs, reversible delayed/undelayed (EF006988) No
With semiconductor output (EF003373) No
Suitable for DIN rail (top hat rail) mounting (EF007250) Yes
Width (EF000008) 22.5 mm
Height (EF000040) 85.6 mm
Depth (EF000049) 103.7 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.