| Ordering | |
|---|---|
| EAN | 4016779851497 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC110004C0210_01 |
| Instructions and Manuals | 1SVC730050M1000 |
| 1SVC730050M0000 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC201310_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.124 kg |
| Technical | |
| Timer Relay Type | True OFF-Delay |
| Time Range | 0.05 s ... 10 minute [unit of time] |
| Rated Control Supply Voltage (Us) | 24 ... 240 V AC/DC |
| Rated Operational Voltage | Auxiliary Circuit 250 V |
| Rated Frequency (f) | 50 / 60 Hz |
| DC | |
| Output | 2 C/O Contacts |
| Terminal Type | Screw Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 1.5 A |
| Minimum Switching Capacity | 12 V |
| 100 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Input Circuit 4 kV |
| Output Circuit 1 / Output Circuit 2 4 kV | |
| Rated Insulation Voltage (Ui) | Input Circuit / Output Circuit 500 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible with Ferrule 1x 0.5 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible 1x 0.5 ... 2.5 mm² | |
| Flexible 2x 0.5 ... 1.5 mm² | |
| Rigid 1x 0.5 ... 4 mm² | |
| Rigid 2x 0.5 ... 2.5 mm² | |
| Tightening Torque | 0.6 ... 0.8 N·m |
| Wire Stripping Length | 8 mm |
| Recommended Screw Driver | 0.8 x 4 |
| 4.5 | |
| Pozidriv 1 | |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| IEC/EN 63000 | |
| IEC/EN 61812-1 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 1x 18-14 AWG |
| Flexible 2x 18-16 AWG | |
| Rigid 1x 20-12 AWG | |
| Rigid 2x 20-14 AWG | |
| Tightening Torque UL/CSA | 7.08 in·lb |
| Pilot Duty UL/CSA | B300 |
| Flammability According to UL94 | V-0 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | bd66a7c7-a9fa-4760-8ddf-0952824f7dea Germany |
| Simplified SCIP | 0691b1cd-d53a-41f0-afc3-0073a38bcd86 Germany |
| 097a4132-482e-4b70-93a1-f23e073e8d64 Italy | |
| 1589c147-173d-413e-a525-501963543794 Portugal | |
| 1873b5be-a8de-4b01-a84d-1c6e6dfdb7fc Germany | |
| 275d668c-5603-45f6-a250-4002c08dea89 Croatia | |
| 346001b2-d21a-4b29-8036-8986df501fd9 Finland | |
| 34b04edb-fe19-419e-9fe6-67b76c3e7121 Netherlands | |
| 3b6e80f3-1c54-431b-a837-1ed0733edc91 Spain | |
| 3d0a1986-295f-4e3b-add5-94b239c6febb Norway | |
| 462b837a-a5c3-4a54-8682-d5e117d12bf5 France | |
| 4d256160-e874-44ba-b720-9e42dee86f3c Hungary | |
| 57688c10-cfe0-4068-9c43-4f285f004673 Sweden | |
| 58bac772-bb19-4d97-89da-4e057443dcd9 Hungary | |
| 693cb17a-0ad9-459f-a953-d5e6fdfda487 Belgium | |
| 861f29db-4729-4853-8ef5-a34797d456c9 Germany | |
| 89451e65-6a11-4f7b-9648-f57d84f5d4e9 Poland | |
| a4dd6bec-2518-4d06-a7cc-c11c1e4eeb9b Greece | |
| ad22ef11-b9fc-451e-a9ac-d28dccbc55bf Poland | |
| b113b1ce-9802-4fbe-9f72-c1ad555f8060 France | |
| bcdc7ed9-fa0c-456e-b132-af2e04afc0b8 Estonia | |
| bddfc9fe-e83a-46ec-ba19-2f05e4bb707c Czech Republic | |
| bf01c481-8828-40df-8139-2d9162441056 Germany | |
| c259e9e7-09a0-4f4f-a28f-8b8485b4a2c7 Poland | |
| cc4ad533-df8e-4f22-b097-d52795e800d1 Bulgaria | |
| f96e9eb7-bb6d-4795-be57-2d8a59ffd884 Denmark | |
| fc21a40c-7825-46b5-bc98-d3f89108f0f3 Sweden | |
| fc9b0e5e-67d9-4eaa-a18c-f16daef8d2a7 Belgium | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| Environmental Product Declaration - EPD | 1SAC200371M0001 |
| Certificates and Declarations | |
| CQC Certificate | CQC2007010303255979 |
| cULus Certificate | cULus508_20110711-E140448A |
| Declaration of Conformity - CCC | 2020980303000207 |
| Declaration of Conformity - CE | 1SVD981008 |
| Declaration of Conformity - UKCA | 1SVD981008-10 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.146 kg |
| Package Level 1 EAN | 4016779851497 |
| External Classifications and Standards | |
| Object Classification Code | K |
| ETIM 7 | EC001439 - Timer relay |
| ETIM 8 | EC001439 - Timer relay |
| ETIM 9 | EC001439 - Timer relay |
| eClass | V11.0 : 27371605 |
| UNSPSC | 39122329 |
| E-Number (Finland) | 2712207 |
| E-Number (Norway) | 4187962 |
| E-Number (Sweden) | 4033119 |
| Feature Name | Feature Value |
|---|---|
| Type of electric connection (EF003961) | Screw connection |
| Function delay-on energization (EF003374) | No |
| Function delay on de-energization (EF003401) | Yes |
| Function floating contact on energization (EF003378) | No |
| Function floating contact on de-energization (EF003402) | No |
| Function star-delta (EF003380) | No |
| Function pulse shaping (EF003403) | No |
| Function flashing, starting with pause, fixed time (EF003363) | No |
| Function flashing, starting with pulse, fixed time (EF003364) | No |
| Clock function, starting with pause, variable (EF003365) | No |
| Clock function, starting with pulse, variable (EF003366) | No |
| Remote operation possible (EF003361) | No |
| Suitable as remote control (EF003362) | No |
| Pluggable on auxiliary contact block (EF006952) | No |
| Rated control supply voltage AC 50 Hz (EF003978) | 24 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 24 V |
| Rated control supply voltage DC (EF003980) | 24 V |
| Voltage type for actuating (EF008242) | AC/DC |
| Nominal current (EF000001) | 4 A |
| Time range (EF003384) | 0.05 s |
| Number of outputs, undelayed, normally closed contact (EF006835) | 0 |
| Number of outputs, undelayed, normally open contact (EF006836) | 0 |
| Number of outputs, undelayed, change-over contact (EF006837) | 2 |
| Number of outputs, delayed, normally closed contact (EF006838) | 0 |
| Number of outputs, delayed, normally open contact (EF006839) | 0 |
| Number of outputs, delayed, change-over contact (EF006840) | 2 |
| Outputs, reversible delayed/undelayed (EF006988) | No |
| With semiconductor output (EF003373) | No |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | Yes |
| Width (EF000008) | 22.5 mm |
| Height (EF000040) | 85.6 mm |
| Depth (EF000049) | 103.7 mm |