View larger
1SFL558029R7811 ABB CONTACTOR AM300-30-11 110-125V 50/60Hz / DC
1SFL558029R7811
11110
ABB
1 Pcs.
Automation > Power contactor, AC switching
"A" SECRLP
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Abb 1SFL558029R7811 is an industrial-grade contactor designed to safely manage exceptionally large currents in heavy motor control and power distribution networks. These high-capacity devices are critical for handling heavy electrical loads within demanding commercial and industrial facilities. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of Main Contacts NO: 3
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 1
- Rated Operational Voltage: Main Circuit 690 V
- Rated Frequency (f): Main Circuit 50/60 Hz
- Conventional Free-air Thermal Current (I th ): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 500 A
- Rated Operational Current AC-1 (I e ): (690 V) 55 °C 400 A (690 V) 40 °C 500 A (690 V) 70 °C 325 A
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Short-Circuit Protective Devices: gG Type Fuses 500 A
- Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour
- Rated Operational Current DC-1 (I e ): (110 V) 2 Poles in Series, 40 °C 450 A (220 V) 3 Poles in Series, 40 °C 450 A
- Rated Operational Current DC-3 (I e ): (110 V) 2 Poles in Series, 40 °C 450 A (220 V) 3 Poles in Series, 40 °C 450 A
- Rated Operational Current DC-5 (I e ): (110 V) 2 Poles in Series, 40 °C 450 A (220 V) 3 Poles in Series, 40 °C 450 A
- Rated Insulation Voltage (U i ): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
More info
▲A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Magnetically latch, control voltage 110-125 V, AC/DC latch
Ordering
- EAN:
- 7320500356920
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85364900
Dimensions
- Product Net Width:
- 164.0mm
- Product Net Depth:
- 180.5mm
- Product Net Height:
- 227.0mm
- Product Net Weight:
- 6.100kg
Container Information
- Package Level 1 Units:
- 1 piece
- Package Level 1 Width:
- 200 mm
- Package Level 1 Length:
- 220 mm
- Package Level 1 Height:
- 280 mm
- Package Level 1 Gross Weight:
- 6.1 kg
- Package Level 1 EAN:
- 7320500356920
Technical
- Number of Main Contacts NO:
- 3
- Number of Main Contacts NC:
- 0
- Number of Auxiliary Contacts NO:
- 1
- Number of Auxiliary Contacts NC:
- 1
- Rated Operational Voltage:
- Main Circuit 690 V
- Rated Frequency (f):
- Main Circuit 50/60 Hz
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors q = 40 °C 500 A
- Rated Operational Current AC-1 (Ie):
- (690 V) 55 °C 400 A
(690 V) 40 °C 500 A
(690 V) 70 °C 325 A
- Rated Operational Current AC-3 (Ie):
- (415 V) 55 °C 300 A
(690 V) 55 °C 280 A
(220 / 230 / 240 V) 55 °C 305 A
(440 V) 55 °C 280 A
(380 / 400 V) 55 °C 305 A
(500 V) 55 °C 280 A
- Rated Operational Power AC-3 (Pe):
- (500 V) 200 kW
(220 / 230 / 240 V) 90 kW
(690 V) 250 kW
(380 / 400 V) 160 kW
(440 V) 160 kW
(415 V) 160 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
- 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
- 10 x Ie AC-3
- Short-Circuit Protective Devices:
- gG Type Fuses 500 A
- Rated Short-time Withstand Current (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A
- Maximum Breaking Capacity:
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
- Maximum Electrical Switching Frequency:
- AC-3 300 cycles per hour
AC-1 300 cycles per hour
AC-2 / AC-4 150 cycles per hour
- Rated Operational Current DC-1 (Ie):
- (110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
- Rated Operational Current DC-3 (Ie):
- (110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
- Rated Operational Current DC-5 (Ie):
- (110 V) 2 Poles in Series, 40 °C 450 A
(220 V) 3 Poles in Series, 40 °C 450 A
- Rated Insulation Voltage (Ui):
- acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
- Rated Impulse Withstand Voltage (Uimp):
- Main Circuit 8 kV
- Mechanical Durability:
- 5 million
- Maximum Mechanical Switching Frequency:
- 300 cycles per hour
- Coil Operating Limits:
- (acc. to IEC 60947-4-1)0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
- Rated Control Circuit Voltage (Uc):
- 60 Hz 110…125 V
50 Hz 110…125 V
DC Operation 110…125 V
- Coil Consumption:
- Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A
Holding at Max. Rated Control Circuit Voltage DC 2 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 520 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A
- Operate Time:
- Between Coil Energization and NO Contact Closing 50 … 90 ms
Between Coil De-energization and NO Contact Opening 43 … 53 ms
Between Coil De-energization and NC Contact Closing 40 … 50 ms
Between Coil Energization and NC Contact Opening 45 … 85 ms
- Connecting Capacity-Main Circuit:
- Rigid Al-Cable 120…240 mm²
Bar 32 mm
Rigid Cu-Cable 16…240 mm²
- Connecting Capacity-Auxiliary Circuit:
- Solid 2x1…4 mm²
Flexible with Insulated Ferrule 2x0.75…2.5 mm²
Stranded 2x1…4 mm²
Flexible 2x0.75…2.5 mm²
Flexible with Ferrule 2x0.75…2.5 mm²
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
- Connecting terminals (delivered in open position) Main poles:
- Flat type c/w screws and bolts
- Terminal Type:
- Main Circuit: Bars
Environmental
- Ambient Air Temperature:
- Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
Close to Contactor for Storage -40…+70 °C
- Maximum Operating Altitude Permissible:
- 3000 m
- Resistance to Shock acc. to IEC 60068-2-27:
- Shock Direction: A 5 g
Shock Direction: C2 5 g
Shock Direction: C1 5 g
Shock Direction: B2 5 g
Shock Direction: B1 5 g
- RoHS Status:
- Following EU Directive 2002/95/EC August 18, 2005 and amendment
Technical UL/CSA
- Maximum Operating Voltage UL/CSA:
- Main Circuit 600 V
- Horsepower Rating UL/CSA:
- (208 V AC) Three Phase 100 Hp
(440 ... 480 V AC) Three Phase 250 Hp
(550 ... 600 V AC) Three Phase 300 Hp
(220 ... 240 V AC) Three Phase 100 Hp
(200 V AC) Three Phase 100 Hp
Certificates and Declarations (Document Number)
- Declaration of Conformity - CE:
- 1SFA1-93
- GL Certificate:
- GL_20262-04HH
- RINA Certificate:
- ELE060313XG/002
- RMRS Certificate:
- RMRS_12-03683-315
- RoHS Information:
- 1SFC101046D0203
Classifications
- ETIM 5:
- EC000066 - Magnet contactor, AC-switching
- UNSPSC:
- 39121529