View larger
1SVR560730R3402 ABB CM-UFD.M33 Grid feeding monitoring relay 3c/o,L-L 0-540VAC,L-N 0-312VAC
1SVR560730R3402
560730
ABB
1 Pcs.
Automation > Voltage monitoring relay
Monitoring
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB CM-UFD.M33 grid feeding monitoring relay 3c/o,l-l 0-540vac,l-n 0-312vac is a specialized grid disconnection relay used in decentralized power generation systems to monitor voltage and frequency parameters safely. These relays ensure compliance with grid interconnection standards by automatically decoupling alternative energy sources from the main utility grid during power disturbances.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- EAN: 4013614492921
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 2CDC112210D0201
- Instructions and Manuals: 1SVC560512M0000
- CAD Dimensional Drawing: 2CDC001079B0201
- EPLAN Data: 9AAC159149_EPLAN
- Product Net Width: 108 mm
- Product Net Height: 90 mm
- Product Net Depth / Length: 67 mm
- Product Net Weight: 0.304 kg
- Function: Over- and undervoltage monitoring
- Measuring Range: 0 ... 550 V AC
- Rated Control Supply Voltage (U s ): 24 ... 240 V AC/DC
- Output: 3 c/o (SPDT) contacts
- Terminal Type: Screw Terminals
More info
▲| Ordering | |
|---|---|
| EAN | 4013614492921 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112210D0201 |
| Instructions and Manuals | 1SVC560512M0000 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC159149_EPLAN |
| Dimensions | |
| Product Net Width | 108 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 67 mm |
| Product Net Weight | 0.304 kg |
| Technical | |
| Function | Over- and undervoltage monitoring |
| Interrupted neutral monitoring | |
| Over- and underfrequency monitoring | |
| 10 minutes average value monitoring | |
| Vector shift detection | |
| ROCOF monitoring | |
| Measuring Range | 0 ... 550 V AC |
| Rated Control Supply Voltage (Us) | 24 ... 240 V AC/DC |
| Output | 3 c/o (SPDT) contacts |
| Terminal Type | Screw Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Degree of Protection | Housing IP20 |
| Terminals IP20 | |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 10 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 50000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible with Ferrule 1x 0.25 ... 4.0 mm² |
| Flexible with Ferrule 2x 0.25 ... 0.75 mm² | |
| Flexible with Insulated Ferrule 1x 0.25 ... 4.0 mm² | |
| Flexible with Insulated Ferrule 2x 0.25 ... 0.75 mm² | |
| Flexible 1x 0.2 ... 4.0 mm² | |
| Flexible 2x 0.2 ... 1.5 mm² | |
| Rigid 1x 0.2 ... 6.0 mm² | |
| Rigid 2x 0.2 ... 1.5 mm² | |
| Tightening Torque | 0.5 ... 0.6 N·m |
| Wire Stripping Length | 8 mm |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| IEC/EN 63000 | |
| IEC/EN 60255-1 | |
| IEC/EN 60255-127 | |
| IEC/EN 60255-26 | |
| IEC/EN 60255-27 | |
| IEC/EN 61000-6-2 | |
| IEC/EN 61000-6-3 | |
| IEC/EN 60255-181 | |
| UL 508 | |
| ENA EREC G98 | |
| ENA EREC G99 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible with Ferrule 1x 24-12 AWG |
| Flexible with Ferrule 2x 24-18 AWG | |
| Flexible with Insulated Ferrule 1x 24-12 AWG | |
| Flexible with Insulated Ferrule 2x 24-18 AWG | |
| Flexible 1x 24-12 AWG | |
| Flexible 2x 24-16 AWG | |
| Rigid 1x 24-10 AWG | |
| Rigid 2x 24-16 AWG | |
| Tightening Torque UL/CSA | 4.4 ... 5.3 in·lb |
| Pilot Duty UL/CSA | B300 |
| Environmental | |
| Ambient Air Temperature | Operation -20 ... +60 °C |
| Storage -25 ... +50 °C | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| ABB EcoSolutions | |
| Environmental Product Declaration - EPD | 1SAC200393H0001 |
| Certificates and Declarations | |
| cULus Certificate | cUL508us_20140314-E140448 |
| Declaration of Conformity - CE | 1SVD981066-0000 |
| Declaration of Conformity - UKCA | 1SVD981066-1000 |
| TÜV Certificate | ESY_044254 0050 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 121 mm |
| Package Level 1 Depth / Length | 71 mm |
| Package Level 1 Height | 99 mm |
| Package Level 1 Gross Weight | 0.36 kg |
| Package Level 1 EAN | 4013614492921 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC001438 - Voltage monitoring relay |
| ETIM 8 | EC001438 - Voltage monitoring relay |
| ETIM 9 | EC001438 - Voltage monitoring relay |
| eClass | V11.0 : 27371801 |
| UNSPSC | 39122331 |
| E-Number (Finland) | 2712564 |
| E-Number (Norway) | 4188113 |