View larger
1SVR730740R0300
730740
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| EAN | 4016779852739 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112199D0201 |
| Instructions and Manuals | 1SVC730560M1001 |
| 1SVC730560M0001 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC159147_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.151 kg |
| Technical | |
| Function | Overtemperature monitoring |
| Undertemperature monitoring | |
| Over- and undertemperature monitoring | |
| Measuring Range | 0 ... 200 °C |
| Sensor Type | PT100 |
| Rated Control Supply Voltage (Us) | 24 ... 240 V AC/DC |
| Rated Frequency (f) | Supply Circuit 50 Hz |
| Supply Circuit 60 Hz | |
| Supply Circuit DC | |
| Output | 2 x 1 c/o or 1 x 2 c/o contacts, configurable |
| Terminal Type | Screw Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Measuring Circuit / Output Circuit 4 kV |
| Output Circuit 1 / Output Circuit 2 4 kV | |
| Supply Circuit / Measuring Circuit 4 kV | |
| Supply Circuit / Output Circuit 4 kV | |
| Rated Insulation Voltage (Ui) | Measuring Circuit / Output Circuit 300 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Supply Circuit / Measuring Circuit 300 V | |
| Supply Circuit / Output Circuit 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible with Ferrule 1x 0.5 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible 1x 0.5 ... 2.5 mm² | |
| Flexible 2x 0.5 ... 1.5 mm² | |
| Rigid 1x 0.5 ... 4 mm² | |
| Rigid 2x 0.5 ... 2.5 mm² | |
| Tightening Torque | 0.6 ... 0.8 N·m |
| Wire Stripping Length | 8 mm |
| Recommended Screw Driver | 0.8 x 4 |
| 4.5 | |
| Pozidriv 1 | |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.60947-5-1 |
| IEC/EN 60255-26 | |
| IEC/EN 60255-27 | |
| IEC/EN 61000-6-2 | |
| IEC/EN 61000-6-3 | |
| IEC/EN 63000 | |
| UL 60947-5-1 | |
| IEC/EN 60947-5-1 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 1x 18-14 AWG |
| Flexible 2x 18-16 AWG | |
| Rigid 1x 20-12 AWG | |
| Rigid 2x 20-14 AWG | |
| Tightening Torque UL/CSA | 7.08 in·lb |
| Pilot Duty UL/CSA | B300 |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | 2ed6192a-d071-4fe0-8850-e6299e4928cd Germany |
| Simplified SCIP | f49a649d-f527-49b4-916e-3db5b066bc72 Italy |
| a0ec96e2-8624-4576-84c5-c2cf609ca06c Belgium | |
| ba2f8808-f2e9-4f67-b1b7-fb170147bd7c Hungary | |
| da51220f-76d8-4cc9-84f6-819578acef28 Spain | |
| d5a891ab-3ca0-4f14-a4eb-71755f90b0e3 Estonia | |
| ef0cb510-4696-4c4a-9801-68db4b59d2b6 Poland | |
| 5030a36a-bdbe-4b5b-bd6e-e46e855ae360 Netherlands | |
| 00cf8063-65bb-4553-a8ba-99458985d51e Portugal | |
| 36b3f65a-2947-41cd-89b9-edbe5b8f8ccf Hungary | |
| ba16262c-11c8-44b1-ae8c-d209d4419059 Greece | |
| 06b93c3d-926e-46da-bc36-0bb9dceb2210 Sweden | |
| fc4961cf-fd86-4a13-94a5-575da3907c41 Bulgaria | |
| 1a051d11-9dd7-44f7-8d49-bb1da95e0b0c France | |
| 481dc0ac-3562-4e3a-b651-73a9126eb53d Poland | |
| 10566f2b-5828-4a98-9f6f-3faca96e6672 Sweden | |
| 23949fcf-add9-4206-87d5-f8ea912c9d50 Germany | |
| ba2cccb5-e38d-43fa-baa8-116f8a2d9a79 Germany | |
| dc9e38c9-4b81-47b7-8ebd-aff1ea09e620 France | |
| 60ccdc39-7fe7-4d01-9378-641f853f1df9 Croatia | |
| 6e5c6e4d-ec41-4a14-a48b-cf6b48ce026b Czech Republic | |
| 4db759f7-6fb0-4ecf-94b1-bc24d2a4234d Germany | |
| b6783975-0208-4e81-81b9-df73c064f14f Belgium | |
| 890ca41c-7d59-4cbc-811e-7c13f2b9c42a Poland | |
| 3b36f806-ed58-4537-9cf7-62495e193937 Norway | |
| a1590ff4-2a7a-4ef9-85f2-6c411207b83d Denmark | |
| a0dfb82f-54c2-4c9f-a2ce-cbecbd06dd88 Finland | |
| fdfac905-7958-4db5-9ee5-2606d6540286 Germany | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
| Certificates and Declarations | |
| CCC Certificate | CCC_2018010303056014 |
| CQC Certificate | CQC2007010303243843 |
| cULus Certificate | cULus60947-5-1_20170922-E140448 |
| Declaration of Conformity - CCC | 2020980303000196 |
| Declaration of Conformity - CE | 1SVD981015-00 |
| Declaration of Conformity - UKCA | 1SVD981015-10 |
| DNV GL Certificate | DNV_GL_TAA000021M |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.176 kg |
| Package Level 1 EAN | 4016779852739 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC001446 - Temperature monitoring relay |
| ETIM 8 | EC001446 - Temperature monitoring relay |
| ETIM 9 | EC001446 - Temperature monitoring relay |
| eClass | V11.0 : 27371810 |
| UNSPSC | 39122331 |
| E-Number (Finland) | 2712326 |
| E-Number (Norway) | 4187810 |
| E-Number (Sweden) | 3860665 |
| Feature Name | Feature Value |
|---|---|
| Type of electric connection (EF003961) | Screw connection |
| With detachable clamps (EF003340) | No |
| Number of measuring circuits (EF003425) | 1 |
| Error registration possible (EF003423) | No |
| External reset possible (EF003426) | No |
| Number of contacts as normally closed contact (EF008255) | 0 |
| Number of contacts as normally open contact (EF008256) | 0 |
| Number of contacts as change-over contact (EF008257) | 2 |
| Temperature measuring range (EF009788) | 0 °C |
| Width (EF000008) | 22.5 mm |
| Height (EF000040) | 85.6 mm |
| Depth (EF000049) | 103.7 mm |