ABB 1SVR730740R0300 1SVR730740R0300 ABB CM-TCS.13S Temperature monitoring relay Temp.-range 0...+200°C, 24-240VAC/DC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR730740R0300 ABB CM-TCS.13S Temperature monitoring relay Temp.-range 0...+200°C, 24-240VAC/DC

1SVR730740R0300

730740

ABB

1 Pcs.

CM-TCS.13S Temperature monitoring relay Temp.-range 0...+200°C, 24-240VAC/DC CM-TCS.13S RELe CTL TEMP 0/200ºC 1 C/C T

Automation > Temperature monitoring relay
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4016779852739
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112199D0201
Instructions and Manuals1SVC730560M1001
1SVC730560M0001
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC159147_EPLAN
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.151 kg
Technical
FunctionOvertemperature monitoring
Undertemperature monitoring
Over- and undertemperature monitoring
Measuring Range0 ... 200 °C
Sensor TypePT100
Rated Control Supply Voltage (Us)24 ... 240 V AC/DC
Rated Frequency (f)Supply Circuit 50 Hz
Supply Circuit 60 Hz
Supply Circuit DC
Output2 x 1 c/o or 1 x 2 c/o contacts, configurable
Terminal TypeScrew Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Measuring Circuit / Output Circuit 4 kV
Output Circuit 1 / Output Circuit 2 4 kV
Supply Circuit / Measuring Circuit 4 kV
Supply Circuit / Output Circuit 4 kV
Rated Insulation Voltage (Ui)Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Measuring Circuit 300 V
Supply Circuit / Output Circuit 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque0.6 ... 0.8 N·m
Wire Stripping Length8 mm
Recommended Screw Driver0.8 x 4
4.5
Pozidriv 1
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.60947-5-1
IEC/EN 60255-26
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
IEC/EN 63000
UL 60947-5-1
IEC/EN 60947-5-1
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Tightening Torque UL/CSA7.08 in·lb
Pilot Duty UL/CSAB300
Environmental
Ambient Air TemperatureOperation -40 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIP2ed6192a-d071-4fe0-8850-e6299e4928cd Germany
Simplified SCIPf49a649d-f527-49b4-916e-3db5b066bc72 Italy
a0ec96e2-8624-4576-84c5-c2cf609ca06c Belgium
ba2f8808-f2e9-4f67-b1b7-fb170147bd7c Hungary
da51220f-76d8-4cc9-84f6-819578acef28 Spain
d5a891ab-3ca0-4f14-a4eb-71755f90b0e3 Estonia
ef0cb510-4696-4c4a-9801-68db4b59d2b6 Poland
5030a36a-bdbe-4b5b-bd6e-e46e855ae360 Netherlands
00cf8063-65bb-4553-a8ba-99458985d51e Portugal
36b3f65a-2947-41cd-89b9-edbe5b8f8ccf Hungary
ba16262c-11c8-44b1-ae8c-d209d4419059 Greece
06b93c3d-926e-46da-bc36-0bb9dceb2210 Sweden
fc4961cf-fd86-4a13-94a5-575da3907c41 Bulgaria
1a051d11-9dd7-44f7-8d49-bb1da95e0b0c France
481dc0ac-3562-4e3a-b651-73a9126eb53d Poland
10566f2b-5828-4a98-9f6f-3faca96e6672 Sweden
23949fcf-add9-4206-87d5-f8ea912c9d50 Germany
ba2cccb5-e38d-43fa-baa8-116f8a2d9a79 Germany
dc9e38c9-4b81-47b7-8ebd-aff1ea09e620 France
60ccdc39-7fe7-4d01-9378-641f853f1df9 Croatia
6e5c6e4d-ec41-4a14-a48b-cf6b48ce026b Czech Republic
4db759f7-6fb0-4ecf-94b1-bc24d2a4234d Germany
b6783975-0208-4e81-81b9-df73c064f14f Belgium
890ca41c-7d59-4cbc-811e-7c13f2b9c42a Poland
3b36f806-ed58-4537-9cf7-62495e193937 Norway
a1590ff4-2a7a-4ef9-85f2-6c411207b83d Denmark
a0dfb82f-54c2-4c9f-a2ce-cbecbd06dd88 Finland
fdfac905-7958-4db5-9ee5-2606d6540286 Germany
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
ABB EcoSolutionsYes
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
CCC CertificateCCC_2018010303056014
CQC CertificateCQC2007010303243843
cULus CertificatecULus60947-5-1_20170922-E140448
Declaration of Conformity - CCC2020980303000196
Declaration of Conformity - CE1SVD981015-00
Declaration of Conformity - UKCA1SVD981015-10
DNV GL CertificateDNV_GL_TAA000021M
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.176 kg
Package Level 1 EAN4016779852739
External Classifications and Standards
Object Classification CodeB
ETIM 7EC001446 - Temperature monitoring relay
ETIM 8EC001446 - Temperature monitoring relay
ETIM 9EC001446 - Temperature monitoring relay
eClassV11.0 : 27371810
UNSPSC39122331
E-Number (Finland)2712326
E-Number (Norway)4187810
E-Number (Sweden)3860665

ETIM for 1SVR730740R0300 Relays (EC001446)
Feature Name Feature Value
Type of electric connection (EF003961) Screw connection
With detachable clamps (EF003340) No
Number of measuring circuits (EF003425) 1
Error registration possible (EF003423) No
External reset possible (EF003426) No
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as normally open contact (EF008256) 0
Number of contacts as change-over contact (EF008257) 2
Temperature measuring range (EF009788) 0 °C
Width (EF000008) 22.5 mm
Height (EF000040) 85.6 mm
Depth (EF000049) 103.7 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.