View larger
1SVR740740R0200
740740
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| EAN | 4016779852784 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112199D0201 |
| Instructions and Manuals | 1SVC730560M1001 |
| 1SVC730560M0001 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC159147_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.14 kg |
| Technical | |
| Function | Overtemperature monitoring |
| Undertemperature monitoring | |
| Over- and undertemperature monitoring | |
| Measuring Range | 0 ... 100 °C |
| Sensor Type | PT100 |
| Rated Control Supply Voltage (Us) | 24 ... 240 V AC/DC |
| Rated Frequency (f) | Supply Circuit 50 Hz |
| Supply Circuit 60 Hz | |
| Supply Circuit DC | |
| Output | 2x 1 C/O or 1x 2 C/O Contact, Configurable |
| Terminal Type | Screwless Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Measuring Circuit / Output Circuit 4 kV |
| Output Circuit 1 / Output Circuit 2 4 kV | |
| Supply Circuit / Measuring Circuit 4 kV | |
| Supply Circuit / Output Circuit 4 kV | |
| Rated Insulation Voltage (Ui) | Measuring Circuit / Output Circuit 300 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Supply Circuit / Measuring Circuit 300 V | |
| Supply Circuit / Output Circuit 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible with Ferrule 2x 0.5 ... 1.5 mm² |
| Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible 2x 0.5 ... 1.5 mm² | |
| Rigid 2x 0.5 ... 1.5 mm² | |
| Wire Stripping Length | 8 mm |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.60947-5-1 |
| IEC/EN 60255-26 | |
| IEC/EN 60255-27 | |
| IEC/EN 61000-6-2 | |
| IEC/EN 61000-6-3 | |
| IEC/EN 63000 | |
| UL 60947-5-1 | |
| IEC/EN 60947-5-1 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 2x 18-16 AWG |
| Rigid 2x 20-16 AWG | |
| Pilot Duty UL/CSA | B300 |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | eecb6332-c24d-44a4-8cad-1ce48addf262 Germany |
| Simplified SCIP | 579a303d-1507-4f4f-a76c-1d347d746537 Germany |
| 2909eef3-cec3-4496-b182-7cf19d73accf Netherlands | |
| 67f4a178-1b7f-4b48-a6ef-9d9e8fc6a0d6 Greece | |
| 3aa9d88e-a623-4e84-b671-27ba3aa83345 Portugal | |
| d3e8f8e3-c5f9-47d5-843f-d4fff0d1bd5d Hungary | |
| 2503e87f-2322-43ca-89f2-6acd5907b89d Belgium | |
| 194bc82f-170f-4c4b-abd0-410817eb0519 Bulgaria | |
| f401a977-a23c-4664-b9ce-861b9729ac5c Denmark | |
| be7e20af-ffa9-401d-84ec-88e656464d7e Germany | |
| 66f6c1ac-30c1-4b75-b516-f5598980921e Czech Republic | |
| d691d61f-043a-4891-9791-d9ba7cd995b1 Poland | |
| 77a79d1a-87ab-4edf-b7bd-2054bc3a2612 Sweden | |
| de2bdfc7-addb-4a8d-9942-b7e9d1879ee4 Poland | |
| 318bf6be-bb88-4d58-a46c-9f0dca074a15 France | |
| 75f7e696-3672-49fa-a09b-952dc9ec3811 Germany | |
| 08621042-94b6-43fc-8055-d563d171a4b5 Hungary | |
| af212771-3438-4dce-8563-6260e9630c63 Estonia | |
| 3dc39869-72ba-44b8-a930-be4a6f022351 Croatia | |
| f94e00aa-0092-4ba8-901c-94ee52941f71 Spain | |
| a68ddf6b-334d-4c06-a2f9-bed7c3a13bbf Sweden | |
| 599538bd-b809-44b8-8d8b-077d85585db5 France | |
| e11b3d90-2b39-42eb-8a5a-eb763076e7b4 Finland | |
| 44266071-e147-4f00-9ec6-70b5353e368c Italy | |
| 6c99c8f0-2e0e-46a6-ab6f-f5920c2a3942 Germany | |
| b903b667-5fe7-49d8-8f96-04e3cd9a31e4 Poland | |
| a63c7445-a912-42e5-8c7b-eaf90cbc776f Norway | |
| fa88c0b1-57d7-407e-aed4-389d94f5c867 Belgium | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
| Certificates and Declarations | |
| CCC Certificate | CCC_2018010303056014 |
| CQC Certificate | CQC2007010303243843 |
| cULus Certificate | cULus60947-5-1_20170922-E140448 |
| Declaration of Conformity - CCC | 2020980303000196 |
| Declaration of Conformity - CE | 1SVD981015-00 |
| Declaration of Conformity - UKCA | 1SVD981015-10 |
| DNV GL Certificate | DNV_GL_TAA000021M |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.165 kg |
| Package Level 1 EAN | 4016779852784 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC001446 - Temperature monitoring relay |
| ETIM 8 | EC001446 - Temperature monitoring relay |
| ETIM 9 | EC001446 - Temperature monitoring relay |
| eClass | V11.0 : 27371810 |
| UNSPSC | 39122331 |
| E-Number (Finland) | 2712323 |
| E-Number (Norway) | 4188191 |
| E-Number (Sweden) | 3860670 |