View larger
1SVR740740R0100
740740
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| EAN | 4016779852777 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112199D0201 |
| Instructions and Manuals | 1SVC730560M1001 |
| 1SVC730560M0001 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC159147_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.14 kg |
| Technical | |
| Function | Overtemperature monitoring |
| Undertemperature monitoring | |
| Over- and undertemperature monitoring | |
| Measuring Range | -50 ... 50 °C |
| Sensor Type | PT100 |
| Rated Control Supply Voltage (Us) | 24 ... 240 V AC/DC |
| Rated Frequency (f) | Supply Circuit 50 Hz |
| Supply Circuit 60 Hz | |
| Supply Circuit DC | |
| Output | 2x 1 C/O or 1x 2 C/O Contact, Configurable |
| Terminal Type | Screwless Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Measuring Circuit / Output Circuit 4 kV |
| Output Circuit 1 / Output Circuit 2 4 kV | |
| Supply Circuit / Measuring Circuit 4 kV | |
| Supply Circuit / Output Circuit 4 kV | |
| Rated Insulation Voltage (Ui) | Measuring Circuit / Output Circuit 300 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Supply Circuit / Measuring Circuit 300 V | |
| Supply Circuit / Output Circuit 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible with Ferrule 2x 0.5 ... 1.5 mm² |
| Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible 2x 0.5 ... 1.5 mm² | |
| Rigid 2x 0.5 ... 1.5 mm² | |
| Wire Stripping Length | 8 mm |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.60947-5-1 |
| IEC/EN 60255-26 | |
| IEC/EN 60255-27 | |
| IEC/EN 61000-6-2 | |
| IEC/EN 61000-6-3 | |
| IEC/EN 63000 | |
| UL 60947-5-1 | |
| IEC/EN 60947-5-1 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 2x 18-16 AWG |
| Rigid 2x 20-16 AWG | |
| Pilot Duty UL/CSA | B300 |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | 06a983bb-2543-4ea2-804e-a463002ec411 Germany |
| Simplified SCIP | f4323184-deed-438c-b498-8dc581e39191 Hungary |
| 80524a8c-97de-48bb-b41d-96a13faa11e3 Spain | |
| 1ecfa2ae-d5c3-42f2-80bb-93b7ed56a8c3 Czech Republic | |
| 86561924-88a6-44d7-9be3-00af1f0cd7a2 Germany | |
| 98762b9c-c610-4abe-8633-47ae35423d4a Germany | |
| 4bdff7c6-9d7d-41ad-bd81-5d81101039e4 Belgium | |
| e8a32a85-1197-4543-8103-8f99c9de7aeb Denmark | |
| d6dbf92a-0c70-4c4f-a1c3-55cbe6a12684 Finland | |
| b95ed30d-1c62-426d-8a2d-3b94774bed8d Norway | |
| 11b070ca-3b08-4d96-825d-fb1e5ff904fd Poland | |
| c315b45d-8f25-4a3f-92f7-f3044e18873a Italy | |
| 1550929f-9c48-4c38-96e8-3fa678c60eff Germany | |
| 032d2567-60ed-4ea1-87ed-5a2246de0325 France | |
| 2bbf7688-9c60-4483-bdbf-97fe58422646 Estonia | |
| 07246a61-ace5-498b-afca-52d8856461ff Croatia | |
| 372e9b3c-ab0a-4a4f-891b-e8748c02c9a3 Poland | |
| 79f0cdb7-a873-479f-8c9a-f77d31da87e7 Hungary | |
| 517ad7cc-0a04-4d8c-87bd-426f306ec178 Netherlands | |
| c1813f1d-2a2e-4414-84fd-2cdaf03d3c43 Portugal | |
| ebd73c50-7b0b-4681-a909-29766ecf6f42 Greece | |
| 54fd55e3-3086-4585-b074-4de99b166cab Bulgaria | |
| dfb484ba-f627-4b5b-9af5-d439640f7de6 Sweden | |
| 99f71afd-2ea5-48bc-a19e-4008a5c068f7 Sweden | |
| 1de26959-2e21-4455-9761-9c0b6b03d4a8 France | |
| 98f863cf-7574-46e8-84ec-627e27f2248d Poland | |
| dc6fdad0-1f00-45ff-a33e-de5a70d90225 Germany | |
| 226ad762-618c-47d2-9092-021d613bde5b Belgium | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
| Certificates and Declarations | |
| CCC Certificate | CCC_2018010303056014 |
| CQC Certificate | CQC2007010303243843 |
| cULus Certificate | cULus60947-5-1_20170922-E140448 |
| Declaration of Conformity - CCC | 2020980303000196 |
| Declaration of Conformity - CE | 1SVD981015-00 |
| Declaration of Conformity - UKCA | 1SVD981015-10 |
| DNV GL Certificate | DNV_GL_TAA000021M |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.165 kg |
| Package Level 1 EAN | 4016779852777 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC001446 - Temperature monitoring relay |
| ETIM 8 | EC001446 - Temperature monitoring relay |
| ETIM 9 | EC001446 - Temperature monitoring relay |
| eClass | V11.0 : 27371810 |
| UNSPSC | 39122331 |
| E-Number (Finland) | 2712321 |
| E-Number (Norway) | 4188190 |
| E-Number (Sweden) | 3860669 |
| Feature Name | Feature Value |
|---|---|
| Type of electric connection (EF003961) | Spring clamp connection |
| With detachable clamps (EF003340) | No |
| Number of measuring circuits (EF003425) | 1 |
| Error registration possible (EF003423) | No |
| External reset possible (EF003426) | No |
| Number of contacts as normally closed contact (EF008255) | 0 |
| Number of contacts as normally open contact (EF008256) | 0 |
| Number of contacts as change-over contact (EF008257) | 2 |
| Temperature measuring range (EF009788) | -50 °C |
| Width (EF000008) | 22.5 mm |
| Height (EF000040) | 85.6 mm |
| Depth (EF000049) | 103.7 mm |