ABB 1SVR740794R1300 1SVR740794R1300 ABB CM-PVS.31P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x160-300VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR740794R1300 ABB CM-PVS.31P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x160-300VAC

1SVR740794R1300

740794

ABB

1 Pcs.

CM-PVS.31P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x160-300VAC CM-PVS.31P RELe CTRL THREE-PHASE 2 C/C RES

Automation > Phase monitoring relay
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4016779852012
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112211D0201
Instructions and Manuals1SVC730730M1000
1SVC730730M0000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132603_EPLAN
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.132 kg
Technical
FunctionPhase failure detection
Phase sequence monitoring
Over- and undervoltage monitoring
Measuring Range(L-L) 160 ... 300 V AC
Time RangeTripping Delay (ON or OFF) 0 second [unit of time]
Rated Control Supply Voltage (Us)(L-L) 160 ... 300 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output2 c/o (SPDT) contacts
Terminal TypeScrewless Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Input Circuit 6 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 600 V
Output Circuit 1 / Output Circuit 2 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 2x 0.5 ... 1.5 mm²
Wire Stripping Length8 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 2x 18-16 AWG
Rigid 2x 20-16 AWG
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIP4900e7c3-484d-4044-899f-947b97d66a30 Germany
Simplified SCIP7d8552ab-0600-4b20-92ca-a927aba32ddc Bulgaria
b608e871-386d-4e94-acc8-5c8f4500b5b5 Portugal
ae2626e0-bc81-4425-b739-2d441c6285ba Estonia
07a57ee6-82bf-4095-b16b-ca2645530f3b Poland
edae461c-85fd-41ad-8631-eedbb8dff2fe Netherlands
1c2cb931-2232-4142-9e19-5e2b4629e091 Hungary
df827d81-8aac-4595-87ba-4d8f27e9a3e7 Greece
c8dbfde9-b8e9-46c6-8bd9-5faef34b3458 Poland
912205f7-4dc9-42cf-aebf-d724ea9b716f France
137fcea8-cdfa-4246-af8f-7ca36a0a66ab France
802c8dcc-84ed-4c61-9159-9e5cf58d0410 Germany
6e40f2ed-fc6e-4cf0-9c6c-1bcb1fd4a2ee Sweden
819b01f1-b119-45c5-8d34-a9d01a028e06 Sweden
1fae5cde-5c72-48ae-88e6-3a1c37bda7d5 Spain
477aefde-f117-4449-9c46-b44909fbc9a2 Hungary
44be524a-1b1f-4a3c-994d-3582c85b0e17 Belgium
e032c28d-530a-48b8-a928-6b5599738b5d Italy
b3fd5182-6c04-4411-97e7-049e453ad907 Germany
39843d90-ff8b-4a54-9296-c03fd93b8577 Czech Republic
c7d6bdac-4b36-4cc7-b54a-8cd74927dc4b Croatia
29ed8ba7-91b7-400f-b7b5-94272f6b6a64 Germany
901c3659-200b-4e77-b7b6-fc7bf51fdbe6 Denmark
7195001b-9a5c-4390-b416-7685cbcb1fae Finland
c981a2b2-d29e-4fa6-8c76-2e2720fbf208 Poland
596de747-a62a-47a1-b40f-d2622ea5340c Norway
e846d94e-e528-42b5-9841-a7f6cf89c38d Belgium
0a4cae25-19a5-4617-b4a8-77852a94c72f Germany
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
CQC CertificateCQC2009010303326655
cULus CertificatecULus508_20120829-E140448
Declaration of Conformity - CCC2020980303000197
Declaration of Conformity - CE1SVD981014-00
Declaration of Conformity - UKCA1SVD981014-10
DNV GL CertificateDNV_GL_TAA000017D
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.157 kg
Package Level 1 EAN4016779852012
External Classifications and Standards
Object Classification CodeB
ETIM 7EC001441 - Phase monitoring relay
ETIM 8EC001441 - Phase monitoring relay
ETIM 9EC001441 - Phase monitoring relay
eClassV11.0 : 27371803
UNSPSC39122332
E-Number (Finland)2712291
E-Number (Norway)4188154
E-Number (Sweden)3860602

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.