View larger
1SVR550871R9500
123320
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| EAN | 4013614348112 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112190D0201 |
| Instructions and Manuals | 1SVC550510M0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 78 mm |
| Product Net Depth / Length | 78.5 mm |
| Product Net Weight | 0.066 kg |
| Technical | |
| Function | Phase failure detection |
| Over- and undervoltage monitoring | |
| Sub-Function | Phase loss |
| Sub-Function 2 | 02 Over- and undervoltage (fixed) |
| Measuring Range | (L-L) 320 ... 460 V AC |
| Time Range | Tripping Delay (ON or OFF) 500 ms |
| Rated Control Supply Voltage (Us) | (L-L) 320 ... 460 V AC |
| Rated Frequency (f) | Supply Circuit 50/60 Hz |
| Output | 1 n/o contact |
| Terminal Type | Screw Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Rated Impulse Withstand Voltage (Uimp) | Input Circuit 4 kV |
| Rated Insulation Voltage (Ui) | Input Circuit / Output Circuit 400 V |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 10 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Connecting Capacity | Flexible with Ferrule 2x 0.75 ... 1.5 mm² |
| Flexible 2x 1 ... 1.5 mm² | |
| Rigid 2x 0.75 ... 1.5 mm² | |
| Tightening Torque | 0.6 ... 0.8 N·m |
| Wire Stripping Length | 10 mm |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| IEC/EN 63000 | |
| IEC/EN 61000-6-2 | |
| IEC/EN 61000-6-3 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 250 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible with Ferrule 2x 18-16 AWG |
| Flexible 2x 18-16 AWG | |
| Rigid 2x 18-16 AWG | |
| Tightening Torque UL/CSA | 7.08 in·lb |
| Pilot Duty UL/CSA | B300 |
| Environmental | |
| Ambient Air Temperature | Operation -20 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | b54e6567-6570-4d39-a8a5-f838e1bef0ba Germany |
| Simplified SCIP | 45d9b8fd-d63b-464b-af0e-6d8510e96106 Bulgaria |
| ce7e14e7-f204-4f37-ae70-abb118ab834f Poland | |
| a507493a-8d0a-4b11-95d7-82491c703169 Denmark | |
| c36e9b36-7a4c-475b-894a-c86c2bf8b259 Germany | |
| 2ee9291b-9c7a-4bef-806b-ce151badf916 Czech Republic | |
| 473c0df2-cb24-47a5-b894-0ece5c25a90f Italy | |
| cbd7c5d1-2a87-4e11-aedd-ee9954e5ede6 Germany | |
| acbb8cad-1ae8-45dd-9f3a-f238b03629ca Netherlands | |
| f7ee0835-eae1-4348-aa2c-cf73360cf163 Finland | |
| 0e625803-148b-47dc-b279-2b7c10db1f33 France | |
| 299b8529-a702-44ac-a124-cbd83de7f43e Greece | |
| 15f15a42-8ee7-423f-a58d-10d6367e6dfe Sweden | |
| 14cd1d68-94fc-4c24-8ab0-26de7f91d2b8 Portugal | |
| bbbf4a82-c153-4fc7-9493-05d79c186d08 Norway | |
| c8869a5d-95c0-4931-b530-e209cafd1206 Croatia | |
| 7dd10c17-c5e5-47e3-acb0-a877c2e5ccb3 Sweden | |
| b729ec2d-7d3a-4386-b74d-d6494b35ad01 Poland | |
| 083d8915-610a-46e0-a73e-3fb7f0b36135 Estonia | |
| ca746fb1-5ff1-4e2c-925f-9a733658b0f9 Hungary | |
| 5dbd6902-f306-4629-a52f-cb6abb7f2505 Spain | |
| 1b7d7bb8-ac89-42cb-9f37-dc1b801bdc9b Belgium | |
| 1cb3535d-f620-47cb-8779-2dde7a965634 Hungary | |
| 7b36b382-d2c5-47ad-a93b-583235655d88 Belgium | |
| f97957f2-cb19-4d6b-9e1a-0f41b2c6b673 France | |
| 296c7fbf-bd21-4516-a744-7ad17a1cfadc Germany | |
| 565b04d9-2123-43e1-9531-ffd2bb8eb079 Germany | |
| 10a9f03a-cbca-4549-932c-3e71981c2818 Poland | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| Certificates and Declarations | |
| CCC Certificate | CCC_2013010303605960 |
| CQC Certificate | CQC2013010303605960 |
| cUL Certificate | cUL508_E140448 |
| Declaration of Conformity - CCC | 2020980303000202 |
| Declaration of Conformity - CE | 1SVD981025-00 |
| Declaration of Conformity - UKCA | 1SVD981025-10 |
| UL Certificate | UL508_E140448 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 23 mm |
| Package Level 1 Depth / Length | 82 mm |
| Package Level 1 Height | 82 mm |
| Package Level 1 Gross Weight | 0.078 kg |
| Package Level 1 EAN | 4013614348112 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC001441 - Phase monitoring relay |
| ETIM 8 | EC001441 - Phase monitoring relay |
| ETIM 9 | EC001441 - Phase monitoring relay |
| eClass | V11.0 : 27371803 |
| UNSPSC | 39122332 |
| E-Number (Finland) | 2712602 |
| E-Number (Norway) | 4187171 |