ABB 1SVR550870R9400 1SVR550870R9400 ABB CM-PVE Phase monitoring relay 1n/o, L1,2,3-N 185-265VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR550870R9400 ABB CM-PVE Phase monitoring relay 1n/o, L1,2,3-N 185-265VAC

1SVR550870R9400

550870

ABB

1 Pcs.

CM-PVE Phase monitoring relay 1n/o, L1,2,3-N=185-265VAC p.on-and-subtens.,1no

Automation > Phase monitoring relay
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4013614348105
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112190D0201
Instructions and Manuals1SVC550510M0002
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width22.5 mm
Product Net Height78 mm
Product Net Depth / Length78.5 mm
Product Net Weight0.069 kg
Technical
FunctionPhase failure detection
Over- and undervoltage monitoring
Interrupted neutral monitoring
Sub-FunctionPhase loss
Sub-Function 202 Over- and undervoltage (fixed)
Measuring Range(L-L) 320 ... 460 V AC
(L-N) 185 ... 265 V AC
Time RangeTripping Delay (ON or OFF) 500 ms
Rated Control Supply Voltage (Us)(L-L) 320 ... 460 V AC
(L-N) 185 ... 265 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output1 N/O Contact
Terminal TypeScrew Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Rated Impulse Withstand Voltage (Uimp)Input Circuit 4 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 400 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 10 A
Output Circuit NO - F Type Fuses 10 A
Connecting CapacityFlexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 2x 0.75 ... 1.5 mm²
Tightening Torque0.6 ... 0.8 N·m
Wire Stripping Length10 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 250 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible with Ferrule 2x 18-16 AWG
Flexible 2x 18-16 AWG
Rigid 2x 18-16 AWG
Tightening Torque UL/CSA7.08 in·lb
Pilot Duty UL/CSAB300
Environmental
Ambient Air TemperatureOperation -20 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIP0029dc96-431d-4c21-a3e5-d008242b8fd6 Germany
Simplified SCIP035eec1f-ec37-4945-8087-7a391717e864 Poland
12eee281-b8f8-47ac-b384-ac022872d939 Belgium
148a98fe-c16b-47f3-8cb7-adbb31887415 Hungary
1f63376c-1863-4d50-a72c-aa7d5816d7e4 Finland
25b60a32-21ea-46e8-8e5a-43d3ac5ce131 Germany
4222eded-f2de-4415-b804-f53af7f96197 Bulgaria
4543facd-072f-4c6d-ac5f-b0e77891ccad Czech Republic
4f85f8a5-9a2b-4f98-b210-ede0354c06d6 Germany
55c89343-f9b6-4e71-bc56-964949a742cc Spain
662a5cfc-bc45-4050-beb8-84bc608c9850 Denmark
7b533556-cc8f-40ed-b0c7-d2f134bf9962 Poland
84ae8b2b-1222-4bd4-9133-deefacb3cfa3 Sweden
8cb66f18-b0ee-4b5c-9fbe-79cc74a393ba Greece
8f03a329-58c6-4ed9-a60e-16b08d9412b5 Sweden
99dd5abb-005b-4921-b77e-51ed3cce18c1 Hungary
a25c1e9f-2f96-4f70-bb67-e9484a0f3cac Croatia
a8216dcf-e738-43f4-a86d-d90293c103ac Netherlands
aa0c131e-acc7-449b-9eaa-c76b725c43c2 Norway
b71dddaa-d304-4663-a3da-7335981ac894 Portugal
b98ab511-5612-4a32-a506-a8d409c0079d Belgium
bf643592-7e38-4aea-8b73-4c14f14cc24e Poland
c82899be-8681-43f4-978c-f131e74ee2fa Germany
cc0166de-394a-49ed-a1f6-30f1248247b5 Estonia
ccb371fc-87ce-49e5-b08c-3aa60e3f393b Italy
d3db90a8-f8f8-4791-8ee9-e0d625cb388f France
e5708a0b-2625-4887-8f95-53114dc28181 Germany
fccf703e-727a-467c-baa5-90febb108f71 France
Toxic Substances Control Act - TSCA2CMT2023-006536
Certificates and Declarations
CB CertificateCB_DK-8880
CCC CertificateCCC_2013010303605960
CQC CertificateCQC2013010303605960
cUL CertificatecUL508_E140448
Declaration of Conformity - CCC2020980303000202
Declaration of Conformity - CE1SVD981025-00
Declaration of Conformity - UKCA1SVD981025-10
UL CertificateUL508_E140448
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width23 mm
Package Level 1 Depth / Length82 mm
Package Level 1 Height82 mm
Package Level 1 Gross Weight0.08 kg
Package Level 1 EAN4013614348105
Package Level 2 EAN4013614580772
External Classifications and Standards
Object Classification CodeB
ETIM 7EC001441 - Phase monitoring relay
ETIM 8EC001441 - Phase monitoring relay
ETIM 9EC001441 - Phase monitoring relay
eClassV11.0 : 27371803
UNSPSC39122332
E-Number (Finland)2712601
E-Number (Norway)4187170
E-Number (Sweden)3860174

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.